Datalogic Scanning QS2500 Barcode Reader User Manual


 
Product Reference Guide 17
Double Confirm
If this option is enabled, the QS2500 will require a several successful
decodings to confirm the bar code data. Larger settings will make misreads
less likely. If a double confirm is set, the multifield scan function will be
disabled.
Option Bar Code Option
Alphanumeric
Entry
Scanning Mode
Good-read off 00
Momentary 01*
Alternate 02
Timeout off 03
Continue/Scan
Mode
04
Test only 05
Standby Duration
0–99 (sec.)
01–99
10*
Same Bar Code Delay
Time
0–99 (10 msec.)
01–99
50*
Double Confirm
0–99
(0 = no double
confirm)
00–09
00*
Start Program
$$
Exit