Datalogic Scanning TC1100-1200 Scanner User Manual


 
Electrical Connections
25-pin connector
1 Shield earth ground
2 TX transmit data
3 RX receive data
4 RTS request to send
5 CTS clear to send
6 nc not connected
7 SGND signal ground
8 EXT BEEPER external beeper connection
9 VCC+ +5Vdc
10 nc not connected
11 OUT+
12 OUT-
See Figure 1
13 VCC+ +5Vdc
14 nc not connected
15 nc not connected
16 nc not connected
17 nc not connected
18 EXT TRIG+
19 EXT TRIG-
See Figure 2
20 DATAIN_WAND
21 DATAOUT
22 OUT-
23 CLKIN
24 CLKOUT
25 GND power ground
Led Status
ON = Power ON
POWER ON
OFF = Power OFF
ON = Good Read
(the LED will remain ON until status changes)
GOOD READ
OFF = No Read
54
[2.13]
7.6
[0.30]
30.5
[1.20]
31.6
[1.25]
24
[0.94]
9.5
[0.37]
10.4
[0.41]
70.7
[2.78]
68.6
[2.70]
mm
[in.]
17.7
[0.70]
Optical Axis
EXT TRIG+
18
19
+ 5V
TC1100
EXTERNAL TRIGGER
Signal
V
30 Vdc max.
Vext
EXT TRIG-
18
19
+ 5V
TC1100 EXTERNAL TRIGGER
30 Vdc max.
Vext
V
Signal
Ground
EXT TRIG+
EXT TRIG-
Input NPN command using external power Input PNP command using external power
EXTERNAL TRIGGERTC1100
Signal
18
19
+ 5V
13
25
GND
Ground
V
EXT TRIG+
EXT TRIG-
Vcc 5Vdc
EXTERNAL TRIGGERTC1100
18
19
+ 5V
Vcc 5Vdc
13
25
GND
Ground
V
Signal
EXT TRIG+
EXT TRIG-
Input NPN command using TC1100 power Input PNP command using TC1100 power
Figure 2 - Trigger Connections
Basic Commands for TC1100
The TC1100 default configuration can be changed by receiving commands through the RS232
Interface. The command syntax is given below with an example.
Command syntax
$+ Command(s) $- <CR> the new setting will be definitive (stored in FLASH EPROM)
Example:
Baud Rate = 19200
Serial On-Line
Operating Mode
BK0 $- CR
Carriage return character (0D Hex.)
Exit and save new configuration
AC410132CD7
Matrix 2/5 3 bars: no check digit,
variable length code from
1
to
32
characters
$+
Enter configuration environment
Multiple command programming sequence:
Commands:
OPERATING MODES
On-line BK1
Serial On-line BK0
Automatic BK3
Automatic / Lighting System Standby BK2
To enter in Test mode #+DStat1<CR> (does not require $+ or $-)
To exit Test mode #+DStat0<CR> (does not require $+ or $-)
GENERAL FEATURES
RS232 interface selection CP0
RS232 Baud Rate CD0 for 150 Baud up to CD8 for 38400 Baud
WEDGE AT CP500
WEDGE Notebook CP505
Keyboard Nationality FJ7 Belgian
FJ4 English
FJ2 French
FJ3 German
FJ1 Italian
FJ6 Spanish
FJ5 Swedish
FJ0 USA
CCD Scan Rate BT0 67 scans/sec
BT1 135 scans/sec
BT2 270 scans/sec
Puzzle Solver AU1 enable AU0 disable
Ink Spread AX1 enable AX0 disable
Decoding safety ED0 1 read
ED1 2 reads
ED2 3 reads
ED3 4 reads
To restore the default configuration $+$*<CR> (does not require $-)
To get configuration from the scanner $+$&<CR> (does not require $-)
Return to RS232 Interface
Ì$+CP0$-$Î
For WEDGE Users
USER INTERFACE
Vext
40 Vdc max
OUT +
11
12
OUT -
TC1100
Figure 1 - Output Connection (Good Read). Example NPN
Physical Dimensions
Width 70.7 mm 2.78 inches
Length 68.6 mm 2.70 inches
Height 30.5 mm 1.20 inches