Datamax datamax-o'neil All in One Printer User Manual


 
6
E) Wrap the Ribbon in a clockwise direction around the Take-Up Hub. Press the TEST Button on the
Front Panel then use the UP / DOWN Buttons to select the RIBBON TEST LABEL. Select a small
quantity of labels and press the ENTER
Key. As the labels are output, observe the flow of the
Ribbon from the Printhead Assembly to the Take-Up Hub. Proceed according to your
observations:
Take-Up
Hub
Printhead
Assembly
llllllllllllllllllllllllll
llllllllllllllllllllllllll
llllllllllllllllllllllllll
llllllllllllllllllllllllll
observe for flow
Ribbon
Front
Panel
If the ribbon flow is smooth, press the CANCEL Key, and then proceed to F; or,
If the ribbon flow is rippling or if bagging is present, slightly loosen both Ribbon Shield Screws
and then move the Ribbon Shield ‘in’ or ‘out’ to smooth the flow of the ribbon. Afterward,
carefully tighten the Ribbon Shield Screws. Print several more labels to verify your adjustment.
When finished, press the CANCEL Key to stop printing.
lllllll llll lll llllllllll lllll
lllllll llll lll llllllllll lllll
Ribbon Shield
Screws
llllllllllllllllllllllllll
llllllllllllllllllllllllll
llllllllllllllllllllllllll
llllllllllllllllllllllllll
Ribbon
Shield