Dell 2970 Server User Manual


 
Getting Started With Your System 11
Video
Video type ATI ES1000 video controller; VGA connector
Video memory 32 MB
Power
AC power supply (per power supply)
Wattage
750 W
Voltage
85–264 VAC, autoranging, 47–63 Hz
Heat dissipation
2697 BTU/hr maximum
Maximum inrush current
Under typical line conditions and over the entire
system ambient operating range, the inrush
current may reach 55 A per power supply for
10 ms or less.
Batteries
System battery
CR 2032 3.0-V lithium ion coin cell
RAID battery (optional)
4.1-V lithium ion
Physical
Rack
Height
8.656 cm (3.40 in)
Width
44.7 cm (17.6 in)
Depth
75.68 cm (29.79 in)
Weight (maximum configuration)
26.76 kg (59 lb)
Environmental
NOTE: For additional information about environmental measurements for specific system configurations,
see www.dell.com/environmental_datasheets.
Temperature
Operating
10° to 35°C (50° to 95°F) with a maximum
temperature gradation of 10°C per hour
NOTE: For altitudes above 2950 feet, the maximum
operating temperature is derated 1ºF/550 ft.
Storage
–40° to 65°C (–40° to 149°F) with a maximum
temperature gradation of 20°C per hour