Dell 5548 Switch User Manual


 
PowerConnect 5500 Series Release Notes
System Firmware Version 4.1.0.1 Subject to Change Without Notice Page 4
PC55xx - show clock detail output
different to user manual
Show clock in the device
showed Summer time range
in dates instead of words
Fixed the code to match the User
Guide
Incorrect OID returned on SNMPGetNext
55xx
When using the SNMP
GetNext on
1.3.6.1.2.1.2.2.1.1.1.9999
the incorrect OID is returned
Fixed the problem
PC55xx - SNMP ifType value of 6 for port-
channel interfaces
ifType for Post-Channels is
the same as for regular
interfaces
Updated the MIB information to
comply newer iANAifType definition
GUI shows a fan led in red which does not
match the physical status of the front led
Once the switch temperature
goes below 40 degrees, the
GUI shows a fan led in red
which does not match the
physical status of the front
led
GUI now shows the right status of
the LED
PC55xx Connectivity issues with fixed
port setting and stacking.
Use 2 PC55xx switches as
stack and with fixed port
setting 100 Full. for example
1/0/1 and 2/0/1
After remove/power of the
master unit, the fixed port
(gi2/0/1) did not do a linkup,
but the LED is on.
Fixed the problem
PC55xx switch crashed on snmpgetnext
1.3.6.1.4.1.89.59.2.3.1.9.2.2
Device crashed when using
snmpgetnext of
1.3.6.1.4.1.89.59.2.3.1.9.2.2
Fixed the problem