RAID controller module Six single-color LEDs:
One battery fault
One cache active
One controller fault
One controller power
One system identification
One management Ethernet activity
Six two-color LEDs:
Four SAS IN link or fault
One SAS OUT link or fault
One management Ethernet link speed
Switch
System identification button Located on the front control panel. This button is
used to locate a system within a rack.
Enclosure mode switch Located on the front of the system. This switch is
not applicable to the PowerVault MD3200 series
storage array.
Password reset switch Located on the back-panel of the RAID controller
module. This switch is used to reset the storage array
password.
Power Supplies
AC power supply (per power supply)
Wa tt ag e
600 W
Voltage
100–240 VAC (8.6 A–4.3 A)
Heat dissipation
100 W
Maximum inrush current
Under typical line conditions and over the entire
system ambient operating range, the inrush current
may reach a maximum of 55 A per power supply for
10 ms or less.