Dell FE100/FL100 Computer Accessories User Manual


 
support.dell.com
Installation Overview 2-5
For the PowerEdge Cluster FE200/FL200, perform the following steps:
a. Install QLDirect on each node and reboot.
b. Set the failover path in the QLogic Fibre Channel Configuration software on
each node.
c. Reboot each node.
d. Install Dell OpenManage Array Manager on each node.
A dialog box appears, asking you if the PowerVault 660F will be used in an
MSCS cluster without storage consolidation. Select Ye s .
e. Reboot node A.
11. Shut down node B.
12. From node A, configure the RAID level on the storage system.
13. Reboot node A.
14. From node A, partition, format, and assign drive letters to the Fibre Channel
hard-disk drives in the storage system using Windows 2000 Disk Management
or Dell OpenManage Array Manager.
15. On node A, verify disk access and functionality on all shared disks.
16. Shut down node A, power on node B, and verify disk access and functionality on
node B.
17. Shut down node B, power on node A, and install and configure the Cluster
ServicesoftwareonnodeA.
18. Reboot node A and verify cluster functionality.
19. Power on node B and install the Cluster Service software on node B.
20. Reboot node B and verify cluster functionality.
21. Install and set up your application programs.
22. Install the Dell OpenManage Cluster Assistant With ClusterX software from the
management console (optional).
23. Record the configuration of the cluster using the data sheets in Appendix B,
Cluster Data Sheets.