Dell M4001Q Switch User Manual


 
Rev 1.0
Mellanox Technologies
18
Appendix A: Specifications
Table 4 - M4001[F, Q] Specification Data
Physical Power and Environmental
H x W x D:
Weight:
Mounting:
SerDes Speeds
Connectors:
12.2 x 1.34 x 10.7 inches
310.7 x 34.1 x 271.8 mm
2.6Kg fully configured
Vertically mounted rack
10, 20, 40, 56 Gb/s per port
QSFP
16 external QSFP connectors
16 internal backplane connectors
Typ Power:
FDR
Passive:
Active:
QDR
Passive:
Active:
Max Power:
FDR
Passive:
Active:
QDR
Passive:
Active:
Dissipated Power:
Power through
connector:
Temperature:
Humidity:
80.66W or 275.22BTUs/hr
108.26W or 369.40BTUs/hr
60.42W or 206.16BTUs/hr
88.02W or 300.34BTUs/hr
84.46W or 288.19BTUs/hr
112.06 or 382.36BTUs/hr
75.83W or 258.74BTUs/hr
103.43W or 352.92BTUs/hr
2.0 W per port maximum
0°C to 40°C
10% - 90% non-condensing
Protocol Support Regulatory Compliance
InfiniBand:
QoS:
Management:
Auto-Negotiation of 10Gb/s, 20Gb/s, or 40
Gb/s, or 56Gb/s
9 InfiniBand Virtual Lanes for all ports
8 Data transport lanes and 1 management
lane
Baseboard, Performance, and Device man-
agement Agents for full InfiniBand In-
Band Management
Safety:
EMC:
ENVIRONMEN-
TAL
US/Canada: cTUVus
EU: IEC60950
International: CB
TUV Bauart
USA: FCC, Class A
Canada: ICES, Class A
EU: CE Mark (EN55022 Class
A, EN55024, EN61000-3-2,
EN61000-3-3)
Japan: VCCI, Class A
Korea: RRL (MIC), Class A
Australia/New Zealand: C-Tick
Class A
EU: IEC 60068-2-64: Random
Vibration
EU: IEC 60068-2-29: Shocks,
Type I / II
EU: IEC 60068-2-32: Fall Test