Dell R420 Personal Computer User Manual


 
Environmental
Operating 20% to 80% (noncondensing) at a maximum wet bulb
temperature of 29 °C (84.2 °F)
Storage 5% to 95% at a maximum wet bulb temperature of 38 °C (100.4 °F)
Maximum vibration
Operating 0.26 G
rms
at 5 Hz–350 Hz (all operation orientations)
Storage 1.87 G
rms
at 10 Hz–500 Hz for 15 min (all six sides tested)
Maximum shock
Operating One shock pulse in the positive z axis (one pulse on each side of
the system) of 31 G for 2.6 ms in the operational orientation
Storage Six consecutively executed shock pulses in the positive and
negative x, y, and z axes (one pulse on each side of the system)
of 71 G for up to 2 ms
Six consecutively executed shock pulses in the positive and
negative x, y, and z axes (one pulse on each side of the system)
of 32 G faired square wave pulse with velocity change at 270
inches/second (685 centimeters/second)
Altitude
Operating –15.2 m to 3048 m (–50 ft to 10,000 ft)
NOTE: For altitudes above 2950 ft, the maximum operating
temperature is derated 1 ºF per 550 ft.
Storage –15.2 m to 10,668 m (–50 ft to 35,000 ft)
Airborne contaminant level
Class G1 as defined by ISA-S71.04-1985
8