support.dell.com Dell PowerEdge Cluster SE100, SE200, and SL200 Platform Guide 9
PCI buses
PCI bus 1: PCI slot 1 is 32-bit, 33-MHz
PCI bus 2: PCI slots 2 through 5 are 64-bit, 33-MHz
PCI bus 3: PCI slots 6 and 7 are 64-bit, 33/66-MHz
RAID controllers
RAID controllers can be installed in any available 32-bit, 33-MHz or 64-bit,
33-MHz PCI slot.
If you use multiple RAID controllers and there are available PCI slots, Dell
recommends installing the RAID controllers on separate PCI buses to bal-
ance the load on the system.
NOTICE: The PERC 2/DC is keyed to prevent installation in a 64-bit 33/
66 MHz PCI slot.
NICs
You can install NICs in any available PCI slot.
DRAC 2
If you are currently using a DRAC 2 or plan to use one in the future, install it
in PCI slot 1.
NOTE: To make sure that the SCSI or RAID controller attached to the boot drives
initializes first, you may have to change the scan order of the PCI bus, if the BIOS
supports this option, or change the order of the RAID, NIC, and DRAC 2. Performing
these tasks ensures that Windows numbers the boot drives in the proper sequence.
Adding Peripherals Required for PowerEdge 8450 Cluster
Nodes
WARNING: Hardware installation should be performed only by trained
service technicians. Before working inside the computer system, see the
safety instructions in your PowerEdge system documentation to avoid a
situation that could cause serious injury or death.
The following list provides PCI slot assignment information for the system’s PCI
buses, RAID controllers, NICs, and DRAC 2.
PCI buses
PCI bus 1: PCI slots 1 and 2 are 64-bit, 33-MHz
PCI bus 2: PCI slots 3 through 6 are 64-bit, 33-MHz
PCI bus 3: PCI slots 7 and 8 are 64-bit, 33/66-MHz
PCI bus 4: PCI slots 9 through 10 are 64-bit, 33/66-MHz