Delta Electronics GBIC-1250B5QR Network Card User Manual


 
GBIC-1250B5QR
DELTA ELECTRONICS, INC.
6 2008/01
Rev. 0A
www.deltaww.com
GBIC module definition parameters
Module
Definition
MOD_DEF(0)
Pin 4
MOD_DEF(1)
Pin 5
MOD_DEF(2)
Pin 6
Interpretation by host Reference
0 NC NC NC GBIC not present clause
1 NC NC TTL LOW
Copper Style 1 or Style 2 connector, 1.0625 Gbd,
100-TW-EL-S or 100-TP-EL-S, active
inter-enclosure connection and IEEE802.3
1000BASE-CX
2 NC TTL LOW NC
Copper Style 1 or Style 2 connector, 1.0625 Gbd,
100-TW-EL-S, or 100-TP-EL-S, active or passive
intra-enclosure connection
3 NC TTL LOW TTL LOW Optical LW, 1.0625 Gbd 100-SM-LC-L
4 TTL LOW SCL SDA Serial module definition protocol
5 TTL LOW NC TTL LOW
Optical SW, 1.0625 Gbd 100-M5-SN-I or
100-M6-SN-I
6 TTL LOW TTL LOW NC
Optical LW, 1.0625 Gbd 100-SM-LC-L and similar
to 1.25 Gbd IEEE802.3z 1000BASE-LX, single
mode
7 TTL LOW TTL LOW TTL LOW
Optical SW, 1.0625 Gbd 100-M5-SN-I or
100-M6-SN-I and 1.25 Gbd, IEEE 802.3z,
1000BASE-SX
GBIC timing parameters for GBIC management
Parameter Symbol Min. Max. Unit Unit Conditions
TX_DISABLE assert time t_off 10 μsec
Rising edge of TX_DISABLE to fall of output signal
below 10% of nominal
TX_DISABLE negate
time
t_on 1 mec
Falling edge of TX_DISABLE to rise of output
signal above 90% of nominal
Time to initialize,
includes reset of
TX_FAULT
t_init 300 msec
From power on or hot plug fter V DD T > 4.75 volts
or From negation of TX_DISABLE during reset of
TX_FAULT.
TX_FAULT from fault to
assertion
t_fault 100 μsec
From occurrence of fault (out-put safety violation or
V DD T < 4.5 volts)
TX_DISABLE time to
start reset
t_rest 10 μsec TX_DISABLE HIGH before TX_DISABLE set LOW
RX_LOS assert delay t_loss_on 100 μsec
From detection of loss of signal to assertion of
RX_LOS
RX_LOS negate delay t_loss_off 100 μsec
From detection of presence of signal to negation of
RX_LOS