Delta Electronics Series E36SR Power Supply User Manual


 
DS_E36SR05015_01042008
10
THERMAL CONSIDERATIONS
Thermal management is an important part of the system
design. To ensure proper, reliable operation, sufficient
cooling of the power module is needed over the entire
temperature range of the module. Convection cooling is
usually the dominant mode of heat transfer.
Hence, the choice of equipment to characterize the
thermal performance of the power module is a wind
tunnel.
Thermal Testing Setup
Delta’s DC/DC power modules are characterized in
heated vertical wind tunnels that simulate the thermal
environments encountered in most electronics
equipment. This type of equipment commonly uses
vertically mounted circuit cards in cabinet racks in which
the power modules are mounted.
The following figure shows the wind tunnel
characterization setup. The power module is mounted
on a test PWB and is vertically positioned within the
wind tunnel. The space between the neighboring PWB
and the top of the power module is constantly kept at
6.35mm (0.25’’).
Note: Wind Tunnel Test Setup Figure Dimensions are in millimeters and (Inches)
12.7 (0.5”)
MODULE
A
IR FLOW
50.8
(
2.0”
)
FACING PW
B
PWB
AIR VELOCIT
Y
AND AMBIEN
T
TEMPERATUR
E
MEASURED BELO
W
THE MODUL
E
Figure 20: Wind tunnel test setup
Thermal Derating
Heat can be removed by increasing airflow over the module.
The hottest point temperature of the module is +122°C. To
enhance system reliability; the power module should always
be operated below the maximum operating temperature. If the
temperature exceeds the maximum module temperature,
reliability of the unit may be affected.
THERMAL CURVES
Figure 21: Hot spot temperature measured point.
The allowed maximum hot spot temperature is defined at 122
E36SR05015(Standard) Output Current vs. Ambient Temperature and Air Velocity
@Vin = 24V (Transverse Orientation)
0
2
4
6
8
10
12
14
16
20 25 30 35 40 45 50 55 60 65 70 75 80 85
Ambient Temperature (
)
Output Current(A)
Natural
Convection
200LFM
400LFM
300LFM
100LFM
500LFM
600LFM
Figure 22: Output current vs. ambient temperature and air velocity @
V
in
=24V(Transverse Orientation)
E36SR05015(Standard) Output Current vs. Ambient Temperature and Air Velocity
@Vin = 48V (Transverse Orientation)
0
2
4
6
8
10
12
14
16
20 25 30 35 40 45 50 55 60 65 70 75 80 85
Ambient Temperature (
)
Output Current(A)
Natural
Convection
200LFM
400LFM
300LFM
100LFM
500LFM
600LFM
Figure 23: Output current vs. ambient temperature and air velocity @