Delta Electronics TP02G-AS1 Switch User Manual


 
Z Electrical Specifications
Specifications TP02G-AS1
Display Monochromatic STN LCD
Effective Display Area (W) x (H) = 72 x 22 (unit: mm)
Display Resolution
160×32: ASCII: 5×8, 8×8, 8×12, 8×16
LCD Contrast Adjustment Set by Software, adjust the contrast by the press button in the function table
LCD Backlight Type LED Backlight: Automatic Turn-off Setting
Function / Numeric Keys F0 / 0 ~ F9 / 9, ESC, ENTER and Arrow Keys
External Input Power 24V (3W Max.)
Memory Capacity 256K Byte
CPU Hitachi HD64F3064F
RAM of System 32K Byte
Communication Interface COM1: RS-232 COM2: RS-485
Waterproof Class of Front
Panel
IP65 / NEMA4
Operating Temperature for
Hardware
0 ~ 50°C; 20 ~ 90RH (non-condensing)
Storage Temperature for
Hardware
-20 ~ 60°C
Vibration
5Hzf9Hz = Continuous: 1.75mm / Occasional: 3.5mm
9Hzf150Hz = Continuous: 0.5g / Occasional: 1.0g
Shock
15g peak, 11ms duration, half-sine, three shocks in each direction per axis,
on 3 mutually perpendicular axes (total of 18 shocks)
Radiated Emission CISPR11, Class A
Electrostatic Discharge
Immunity
EN61000-4-2
Radiated Immunity EN61000-4-3
Electrical Fast Transient EN61000-4-4
Weight / Dimensions 0.24kg; 147×97×35.5mm (Width(W) × Height(H) × Deep(D))
Cooling Method Natural Air Cooling
[ Program Copy Card
TP02 series provides Program Copy Card Function to copy user program, system function and passwords that is
different from the copy program. It is used to copy the whole HMI environment settings and application programs
to another HMI rapidly. Using Program Copy Card saves time and manpower. The operation is as follows.
Definition: Program Copy Card PCC, TP Series TP
(TPPCC) (PCCTP)
Step 1 Turn the switch on the PCC to TP ÆPCC Turn the switch on the PCC to PCCÆTP
Step 2 Insert the PCC into the extension slot of TP Insert the PCC into the extension slot of TP
Step 3 Input the power to TP Input the power to TP
Step 4
It will display “remove PCC” on the screen and
power on again.
It will display “remove PCC” on the screen and
power on again.
HMI Display Message
(TPPCC) (PCCTP)
Step 1
If the TP model type does not correspond with the
model type of program of PCC, TP will display “TP
series and PCC is different. Press Enter to
Confirm TP seriesPCC. Press Esc to Exit”.
If there is no program in PCC, TP will display “The
PCC is Empty. PCCTP series is illegal”.
Step 2
TP will display “TPPCC series Please wait!”
during transmission.
TP will display “PCCTP series Please wait!”
during transmission.
Step 3
TP will display “Please Remove the PCC and
Reboot” when transmission is completed.
TP will display “Please Remove the PCC and
Reboot” when transmission is completed.
\ Password Function
If the user forgot the password, the password can be cleared by using the following code: 8888. This universal
code will clear the password and all TP02 series internal programs. The TP02 series will be reset to the factory
settings by using this code also. Please pay close attention when using it.
The password can be the alphabet from A to Z or the number from 0 to 9. But it must use the function
keys F0 ~ F9 to input the password characters. Please refer to the following table.
Function Key Use Method Function Key Use Method
F0
scrolls in a loop as follows
0ABCDEF0
F5 It just can be used to be constant 5.
F1
scrolls in a loop as follows
1GHIJK1
F6 It just can be used to be constant 6.
F2
scrolls in a loop as follows
2LMNOP2
F7 It just can be used to be constant 7.
F3
scrolls in a loop as follows
3QRSTU V3
F8 It just can be used to be constant 8.
F4
scrolls in a loop as follows
4WXYZ4
F9 It just can be used to be constant 9.
] Hardware Operation
When the user wants to startup TP02 series, a 24VDC power is needed. After applying 24VDC power to TP02
series, it will enter into the startup display and then enter the user-designed program. Pressing Esc key and
holding on for 5 seconds can return to system menu. There are five selections in the system menu and are
described below.
SELECTIONS EXPLANAION
Download Program
Use the connection cable (DVPACAB530) to connect the TP02 serial communication
port RS-232 to a PC. Then use the TPEdit software to download an application
program to TP02.
Upload Program
Use the connection cable (DVPACAB530) to connect the TP02 serial communication
port RS-232 to a PC. Then use the TPEdit software to upload an application
program from TP02.
Copy Program
Transfer a program between two TP02 units.
1: transmit programs
2: receive programs
When transmit programs and data between two TP02 units. Set one TP02 to
“Receive Program” mode and the other TP02 to “Transmit Program” mode. Please
use twisted pair wires to connect the two units via the RS-485 ports.
TP02 Settings
There are 8 items that used to modify TP02 system settings:
1. Communication protocol: Setting the address of TP02, the control port of PLC,
and the communication string for either RS-232 or RS-485.
2. Contrast: Adjust the contrast of LCM display screen.
3. Back-light: adjust the automatic turn off time of LCM. Setting range is 00 ~ 99
minutes. If set to 00, the LCM Back-light will not turn off.
4. Buzzer: Used to set the buzzer sound, normal mode or quiet mode.
5. Language Setting: Used to set the displayed language. English, Traditional
Chinese, Simplified Chinese or user defined language.
6. Password setting: Used to set, enable, and disable the password function. If the
password function is enabled, it will require the user to input a password before
entering any system menu. The factory password is 1234.
7. Startup display: Used to select the TP02 startup display. User can select “user
defined” to use the file that designed by TPEdit and download to TP02.
8. Comm. indicator: The user can determine if the RS-232 and RS-485 LEDs will
blink or not during communication.
PLC Connection
There are two methods to connect to PLC:
1. Using TP02 serial communication port (COM1) RS-232: set 8-pin DIP switch to
RS-485 mode and connect the cable (DVPACAB215 or DVPACAB230) to
program communication I/O RS-232C of PLC.
2. Using extension communication port (COM2) RS-485: set 8-pin DIP switch to
RS-485 mode and connect 5-pin removal terminal of extension communication
port to RS-485 of PLC with twisted pair.
Execution
Execute the internal program that download from TPEdit or transmitted from other
TP02 units. When program is in execution, the user can return to system menu by
pressing Escape / Exit (Esc) key for 5 seconds.
^ Communication Connection
TP02G may connect to a PC by using connection able DVPACAB515
PC or TP02 / 04G
1
5
6
9
9 PIN D-SUB
TO PC (RS-232)
TO TP02 / 04G
5
1
9
6
9 PIN D-SUB
9 PIN D-SUB female
Rx 2
GND 5
5 GND
PC COM Port
9 PIN D-SUB female
3 Tx
2 Rx
TP02 / 04G COM Port
Tx 3
TP02G may connect to a DVP-PLC by using connection cable DVPACAB215 / DVPACAB230 /
DVPACAB2A30
1. DVPACAB215 / DVPACAB230
TO PC or TP02 / 04G
1
13
14
1
5
6
9
25 PIN D-SUB
9 PIN D-SUB
TO PLC
MINI DIN TERMINAL
2. DVPACAB2A30
TO PC or TP02 / 04G
1
5
6
9
9 PIN D-SUB
TO PLC
MINI DIN TERMINAL
8 PIN MINI DIN25 PIN D-SUB female
PC / TP COM Port PLC COM1 Port
Tx
2
GND 7
8 PIN MINI DIN9 PIN D-SUB female
PC / TP COM Port
PLC COM1 Port
Rx 2
GND 5
6
8
20
4
5
1
4
6
7
8
4 Rx
8 GND
1,2 5V
1
2
3
4
5
6
7
8
5 Tx
Rx 3
Tx 3
1
2
3
4
5
6
7
8
4 Rx
8 GND
1,2 5V
5 Tx
The Pin definition of 9 PIN D-SUB
3 Tx
5 GND
RS-232 9 PIN D-SUB male
TP02 / 04G COM Port
2 Rx
_ Battery Life
Battery Life
Temperature (°C) -20 0 20 60
Life (Year) 1.972 2.466 2.712 2.835
The content of this instruction sheet may be revised without prior notice. Please consult our distributors or
download the most updated version at http://www.delta.com.tw/industrialautomation