Denon AVC-3808 Network Card User Manual


 
- 14 -
COMMAND PARAMETER
function example
PS TRE UP
TREBLE UP/DOWN , direct change to **dB
PSTRE UP<CR>
TRE DOWN
**:00 to 99 by ASCII , 50=0dB
PSTRE DOWN<CR>
TRE **
---AVR-3808 can be operated from -6 to +6(44 to 56)
PSTRE 50<CR>
TRE ?
Return PSTRE Status
PSTRE ?<CR>
DRC AUTO
DRC direct change
PSDRC AUTO<CR>
DRC LOW
PSDRC LOW<CR>
DRC MID
PSDRC MID<CR>
DRC HI
PSDRC HI<CR>
DRC OFF
PSDRC OFF<CR>
DRC ?
PSDRC ?<CR>
DCO OFF
D.COMP direct change
PSDCO OFF<CR>
DCO LOW
PSDCO LOW<CR>
DCO MID
PSDCO MID<CR>
DCO HIGH
PSDCO HIGH<CR>
DCO ?
Return PSDCO Status
PSDCO ?<CR>
LFE UP
LFE UP/DOWN , direct change to **dB
PSLEE UP<CR>
LFE DOWN
**:00 to 99 by ASCII , 00=0dB, 10=-10dB
PSLFE DOWN<CR>
LFE **
---AVR-3808 can be operated from 0 to -10
PSLFE 10<CR>
LFE ?
Return PSLFE Status
PSLFE ? <CR>
EFF ON
EFFECT ON/OFF , EFFECT LEVEL direct change to **dB
PSEFF UP<CR>
EFF OFF
**:00 to 99 by ASCII , 00=0dB, 10=10dB
PSEFF DOWN<CR>
EFF **
---AVR-3808 can be operated from 1 to 15
PSEFF **<CR>
EFF ?
Return PSEFF Status
PSEFF ?<CR>
DEL UP
DELAY UP/DOWN , direct change to ***dB
PSDEL UP<CR>
DEL DOWN
***:000 to 999 by ASCII , 000=0ms, 300=300ms
PSDEL DOWN<CR>
DEL ***
---AVR-3808 can be operated from 0 to 300
PSDEL ***<CR>
DEL ?
Return PSDEL Status
PSDEL ?<CR>
AFD ON
AFDM ON/OFF
PSAFD ON<CR>
AFD OFF
PSAFD OFF<CR>
AFD ?
Return PSAFD Status
PSAFD ?<CR>
PS COMMAND : "*" parameter uses two or three ASCII characters. (see page4 J) section)