Denon AVR-3808 Network Card User Manual


 
- 27 -
EVENT(or RESPONSE) and PARAMETER list
EVENT PARAMETER
function example
PW ON POWER ON/STANDBY change PWON<CR>
STANDBY PWSTANDBY<CR>
MV ** MASTER VOLUME change , **:00 to 99 by ASCII MV80<CR>
98 = +18dB(MAX)
80 = 0dB
00 = -80dB
99 = ---(MIN)
CV FL ** CHANNEL VOLUME change , **:00,38 to 62 by ASCII CVFL 50<CR>
FR ** 62 = +12dB(MAX) CVFR 50<CR>
C ** 50 = 0dB CVC 50<CR>
SW ** 38 = -12dB(MIN) CVSW 50<CR>
SL ** 00 = OFF (define ONLY SWch in DIRECT mode.) CVSL 50<CR>
SR ** CVSR 50<CR>
SBL ** (at SBch 2SP) CVSBL 50<CR>
SBR ** (at SBch 2SP) CVSBR 50<CR>
SB ** (at SBch 1SP) CVSB 50<CR>
MU ON OUTPUT MUTE ON/OFF change MUON<CR>
OFF MUOFF<CR>
SI PHONO INPUT source change SIPHONO<CR>
CD SICD<CR>
TUNER SITUNER<CR>
DVD SIDVD<CR>
HDP SIHDP<CR>
TV/CBL SITV/CBL<CR>
SAT SISAT<CR>
VCR SIVCR<CR>
DVR SIDVR<CR>
V.AUX SIV.AUX<CR>
The PARAMETER of MV, CV EVENT : Uses two or three ASCII characters. (see page4 J) section)