Dialogic DI0408LSAR2 Network Card User Manual


 
CT Bus jumpers according to instructions in this
section.
Note: If these boards are operating in SCbus
mode, CT Bus (H.100) termination is not required.
The following instructions only apply to the
boards at each end of the CT Bus cable. Only
boards at each end of the CT Bus cable must be
terminated.
P6 provides the jumpers location for the
termination. P6 pins 1 and 2 are used to terminate
the CT Bus, ensuring that proper electrical
characteristics exist on the CT Bus. By factory
default, this jumper is not terminated on the board.
To use the CT Bus:Install the jumper on P6 pins
1 and 2 to terminate the CT Bus at that board.
Only terminate the first and last boards (the
boards located at each end) on the CT Bus
cable.
Do not install a shunt across the pins of P6 pins 1
and 2 on boards located between the end boards
on the CT Bus cable (the shunt must be
disconnected on the P6 pins 1 and 2 jumper to
disable termination).
The P6 pins 1 and 2 jumper terminates the H.100
signals listed in the following table.
Shunt
H.100 signal
terminated
P6, pins 1 and 2
(used on boards at
each end of CT Bus
cable only)
CT_FRAME_(A&B)
CT_C8_(A&B)
P6 pins 3 and 4 terminate the MVIP bus signal
when the corresponding jumper clip is installed.
The signal must be terminated only on boards at
each end of the CT Bus cable.
When pins 1 and 2 are used, use pins 3 and 4 as
well.
Connect to External Power Supply
The Power Module generates -24 volts to power
the station interface loop and -70 volts for ringing.
One Power Module is required per DI0408LSAR2
board when station modules are used. The Power
Module connects to a pre-wired power cable
attached to the DI0408LSAR2 board. See the
Connect Breakout Box and Power Supply figure
on side 1.
NOTE: The figure shows a North American-
compliant power supply cord for connecting to
AC power. Use the appropriate power supply cord
for your location.
Connect to the Breakout Box
1. Open the back of the breakout box and
remove the adhesive pads from the housing.
See the Connect Breakout Box and Power
Supply figure on side 1.
2. Mount the back of the breakout box to the
desired location in one of two ways:
Apply double-sided tape to the side of the
rear panel that touches the mounting surface
and press the tape against the mounting
surface.
Hold the rear panel against the mounting
surface. Insert screws through the screw holes
and fasten the panel to the surface.
3. Insert the front panel into the back panel.
4. Connect the breakout box to the
DI0408LSAR2 board. Refer to the Connect
Breakout Box and Power Supply figure on
side 1.
After Installing the Hardware
Install the software as described in the installation
instructions included with the system software.
For technical
specifications and product information
go to:
http://www.dialogic.com/products.htm.
Warranty and Return
Information
Warranty Period
For specific warranty information for this board, refer to
the Warranty section of the Products page, located at this
URL: http://www.dialogic.com/warranties/.
Contacting Technical Support
Dialogic provides technical support for its products
through a network of value added distributors who are
trained to answer technical questions on installing and
configuring Dialogic
®
products. If you are unsure how
to contact your support channel, please call Dialogic
in the United States at 973-967-6600 (9am-5pm EST)
and we will assist in obtaining the appropriate support
channel. Outside the United States please refer to
http://www.dialogic.com/support/contact to obtain
local contact information.
Dialogic also provides direct support via Dialogic
®
Pro™
Services agreements. For more details of direct support
from Dialogic please refer to:
http://www.dialogic.com/support/DialogicPro.
Returning a Product
To return a board for warranty repair or any other returns,
please refer to the following:
http://www.dialogic.com/support/hwfaults. To return a
board for warranty repair, please refer to the following:
http://www.dialogic.com/support/hwfaults. For all other
returns, contact your vendor or Dialogic Customer Support
(for more information, see
http://www.dialogic.com/support/contact/ ).
Sales Assistance
Sales Assistance
If you have a sales question, please contact your
local Sales Representative or the Regional Sales Office
for your area. Address, telephone and fax numbers, are
available at the Dialogic website located at:
http://www.dialogic.com/contact.htm.
To purchase Dialogic
®
products, please refer to the
following website to locate the appropriate supplier.
http://www.dialogic.com/purchase.htm.
All contents of this document are furnished for informational use only and
are subject to change without notice and do not represent a commitment on
the part of Dialogic Corporation or its subsidiaries (“Dialogic”).
Reasonable effort is made to ensure the accuracy of the information
contained in the document. However, Dialogic does not warrant the
accuracy of this information and cannot accept responsibility for errors,
inaccuracies or omissions that may be contained in this document.
INFORMATION IN THIS DOCUMENT IS PROVIDED IN
CONNECTION WITH DIALOGIC
®
PRODUCTS. NO LICENSE,
EXPRESS OR IMPLIED, BY ESTOPPEL OR OTHERWISE, TO ANY
INTELLECTUAL PROPERTY RIGHTS IS GRANTED BY THIS
DOCUMENT. EXCEPT AS PROVIDED IN A SIGNED AGREEMENT
BETWEEN YOU AND DIALOGIC, DIALOGIC ASSUMES NO
LIABILITY WHATSOEVER, AND DIALOGIC DISCLAIMS ANY
EXPRESS OR IMPLIED WARRANTY, RELATING TO SALE AND/OR
USE OF DIALOGIC PRODUCTS INCLUDING LIABILITY OR
WARRANTIES RELATING TO FITNESS FOR A PARTICULAR
PURPOSE, MERCHANTABILITY, OR INFRINGEMENT OF ANY
INTELLECTUAL PROPERTY RIGHT OF A THIRD PARTY.
Dialogic products are not intended for use in medical, life saving, life
sustaining, critical control or safety systems, or in nuclear facility
applications.
It is possible that the use or implementation of any one of the concepts,
applications, or ideas described in this document, in marketing collateral
produced by or on web pages maintained by Dialogic may infringe one or
more patents or other intellectual property rights owned by third parties.
Dialogic does not provide any intellectual property licenses with the sale of
Dialogic products other than a license to use such product in accordance
with intellectual property owned or validly licensed by Dialogic and no
such licenses are provided except pursuant to a signed agreement with
Dialogic. More detailed information about such intellectual property is
available from Dialogic’s legal department at 9800 Cavendish Blvd., 5
th
Floor, Montreal, Quebec, Canada H4M 2V9. Dialogic encourages all
users of its products to procure all necessary intellectual property
licenses required to implement any concepts or applications and does
not condone or encourage any intellectual property infringement and
disclaims any responsibility related thereto. These intellectual
property licenses may differ from country to country and it is the
responsibility of those who develop the concepts or applications to be
aware of and comply with different national license requirements.
4
3
2
1
P6
Dialogic, Diva, Eicon, Eicon Networks, Eiconcard, Dialogic Pro and
SIPcontrol, among others, are either registered trademarks or trademarks of
Dialogic. Dialogic's trademarks may be used publicly only with permission
from Dialogic. Such permission may only be granted by Dialogic’s legal
department at 9800 Cavendish Blvd., 5th Floor, Montreal, Quebec, Canada
H4M 2V9. Any authorized use of Dialogic's trademarks will be subject to
full respect of the trademark guidelines published by Dialogic from time to
time and any use of Dialogic’s trademarks requires proper
acknowledgement. The names of actual companies and products
mentioned herein are the trademarks of their respective owners.