Edgeport Installation Guide (90000403 Rev. D) – Page 21
If the actual test levels are higher or different
than required, these levels are listed in the
appropriate tables.
EN 55022 Class B (1994 w/A1 1995)
Test
Specification
EN55024
Requirement
Electrostatic
Discharge
EN61000-4-2
+4 kV contact
+8kV air
Radiated
Immunity
EN61000-4-3 3 V/m
Electrical Fast
Transient Burst
EN61000-4-4 1kV (A/C), .5kV (I/O)
Surge EN61000-4-5
2kV common mode
1kV differential mode
Conducted
Immunity
EN61000-4-6 3V rms
Magnetic
Immunity
EN61000-4-8 1 A/m Not Applicable
Voltage Dips &
Interrupts
EN61000-4-11
>95%, 30% & >95%
EN55024 (1998)
Test
Specification
EN55022
Requirement
Radiated
Emissions
— Class B
Conducted
Emissions
CISPR 22 Class B
European Contact
Digi International
Joseph-von-Fraunhofer Str. 23
44227 Dortmund, GERMANY
49-231-9747-0
UL/CSA Safety Information
This device complies with the requirements of
following safety standards below:
UL 1950, 3rd edition
CSA No. 950