Dukane Projectors Projector User Manual


 
9
3. Squeeze the lamp retainer clip to
free lamp. Carefully pull up the used
lamp. Take caution since it may be hot.
Allow time to cool (Step 3).
4. Place new lamp in socket.
Push down until firmly seated.
Avoid skin contact. Oil from
skin can cause discoloration
of the lamp capsule or re-
flector. Hold lamp with a
cloth, tissue or gloved hand.
5. Engage the lamp retainer clip.
6. Close lamp cover and replace cover retainer clips. Replace the
stage by aligning rear edge and then pushing down front until
it locks in place.
Open lamp retainer clip
and pull out the lamp.
S
TEP
3 —
TROUBLESHOOTING
Symptom Probable Cause Solution
Neither lamp or a. Unit unplugged a. Plug unit into
fan operate outlet
b. No power at wall outlet b. Verify outlet
has power
c. Stage not closed c. Close stage
d. Stage installed backwards d. Install stage
correctly
e. Damaged part e. Obtain service
No lamp, fan runs a. Burned-out lamp a. Replace lamp
b. Lamp changer not engaged b. Slide changer arm
into position
c. Lamp not seated in receptacle c. Seat lamp
New lamp installed, a. Defective lamp a. Try another new
lamp still not on, lamp
fan runs b. Defective electrical system b. Obtain service
No fan, lamp on a. Fan is obstructed a. Obtain service
b. Fan motor has burned out b. Obtain service
FOR 3000 & 4000 LUMEN MODELS —