SPECIFICATIONS
DPP4004 DPP4012
Mains power supply
Operational voltage 230 VAC ±10 % 230 VAC ±10 %
internally selectable through bridging 115 VAC ±10 % 115 VAC ±10 %
Mains frequency range 50 … 60 Hz 50 … 60 Hz
Power consumption in idling mode  20 VA  20 VA
Power consumption at nominal load  120 VA  360 VA
Battery power supply
Battery voltage 24 V –10 %/+30% 24 V –10 %/+30 %
Current consumption in idling mode  0.17 A  0.17 A
Current consumption at nominal load 4.1 A 12.1 A
Current power handling capacity
with MAINS REMOTE ON 1 A 1 A
Current power handling capacity
with BATTERY REMOTE ON 1 A 1 A
Current power handling capacity
with DELAY OUT 0.1 A 0.1 A
Input current ON/OFF (TOGGLE) > 2.2 mA = ACTIVE < 1mA = inactive
Input current ON/OFF (MODULES) > 2.2 mA = ON < 1mA = OFF
Output data
Nominal output voltage 24 V 24 V
Nominal output current with forced ventilation 4 A 12 A
Residual voltage standing wave d mV pp < 100mV pp < 100mV pp
Mains stabilization ±1 % ±1 %
Safety EN 60065 EN 60065
Radio interference EN 55022 (B) EN 55022 (B)
EN 50082 - 1 EN 50082 - 1
EN 61000 4-2....4-6 EN 61000 4-2....4-6
ENV 50204 ENV 50204
EN 61000-3-2
EN 61000-3-3
Environmental temperature +5 °C … +40 °C +5 °C … +40 °C
Dimensions (W x H x D) 19" x 2 HU = 483 x 88 x 330 mm
Depth incl. connections 400 mm 400 mm
Weight 7 kg 7 kg
DYNACORD PROMATRIX SYSTEM