Dynex DX-400WPS Power Supply User Manual


 
2
SpecificationsDX-400WPS
Make sure that the red voltage switch (located on the back of the
power supply) is set to the correct voltage setting. The setting for
the United States is 115 V. The setting for Europe and other
countries is 230 V.
Make sure that the system board power supply cable is securely
connected to the system board connector (24 pin or 20 pin).
Make sure that all power supply cables to peripheral devices,
such as hard drives, optical drives, and fans, are securely
connected. Any loose power cable connections may cause the
power supply operate incorrectly.
The power supply may be overloaded. Unplug any unnecessary
components, such as extra drives, then try again.
If the power supply is very hot, check the case fans and the power
supply fan. Replace any faulty case fans, then try again.
Specifications
Input
Output
DC output power distribution
Maximum output: 400 Watts
Combined 3.3 V and 5 V: 120 Watts
Dimensions:
5.5 × 3.4 × 5.9 inches (W × H × L)
150×86×140mm (W×H×L)
Legal notices
FCC warning
This equipment may generate or use radio frequency energy. Changes
or modifications to this equipment may cause harmful interference
unless the modifications are expressly approved in the instruction
manual.The user could lose the authority to operate this equipment if
an unauthorized change or modification is made.
Caution:
Any change or modification to the player not expressly
approved by the manufacturer or its authorized parties could void your
authority to operate the player.
UL statement
Any information or documentation provided to you involving UL Mark
services is provided on behalf of Underwriters Laboratories, Inc.
Products that bear the UL Mark are identical to those that were
evaluated by UL and found to be technically compliant with the UL’s
applicable requirements.
For further information regarding the use of UL marks, please visit the
UL Website at www.ul.com.tw.
Voltage USA: 115 Vac
Europe and others: 230 Vac
Frequency 60 Hz-50 Hz
Current 10.0 A (max.) at 115 Vac/60 Hz
5.0A (max.) at 230Vac/50Hz
Parameter Minimum Nominal Maximum Units
Vin (115 VAC) 90 115 132 VRMS
Vin (230 VAC) 180 230 264 VRMS
Vin frequency 47 --- 63 Hz
Voltage Max. load Min. load Regulation
Ripple and
Noise
+3.3 V 30 A 0.5 A ±5% 50 mV
+5 V 28 A 0.3 A ±5% 50 mV
+12 V1 14 A 1 A ±5% 120 mV
+12 V2 15 A 1 A ±5% 120 mV
-12 V 0.3 A 0 A ±10% 120 mV
+5 Vsb 2.5 A 0 A ±5% 50 mV
09-1153 DX-400WPS_MAN_ENG_V2.book Page 2 Monday, January 11, 2010 9:27 AM