Emerson 65 Surge Protector User Manual


 
Emerson Network Power.com
Emerson Network Power.
The global leader in enabling
Business-Critical Continuity
.
AC Power
Connectivity
DC Power
Embedded Computing
Embedded Power
Monitoring
Outside Plant
Power Switching & Controls
Precision Cooling
Racks & Integrated Cabinets
Services
Surge Protection
Liebert Corporation
1050
Dearborn Drive
P.O.
Box 29186
Col
umbus, Ohio 43229
800 877 9222
Phone (U.S. &
Canada Onl
y)
614 888 0246 Phone (Outside U.S.)
614 841 6022 FAX
Via Leonardo Da Vinci 8
Zona
Industriale Tognana
35028
Piove Di Sacco (PD)
Ital
y
39 049 971
9 111 Phone
39 049 584
1 257 FAX
Emerson Network Power Asia Pacific
7/F., Dah Sing Financial Centre
108 G
loucester Rd, Wanchai
Hong Kong
852 2572
2201 Phone
852 28029250 FAX
liebert.com
Technical Support
800 288 6169 Toll-Free
607 724 2484 Phone
607 722 8713 Fax
UL 1449 RATINGS
Line to Line to Line Neutral
System Voltage Neutral Ground to Line to Ground
120/208 or 120/240 400 V 400 V 800 V 400 V
208, 240, 277 or 277/480 800 V 800 V 1500 V 800 V
Specifications
Surge Current Capacity
Minimum Tested
Single Pulse Surge Current Capacity
Protection Mode Impulses Per Mode Model 100 Model 80 Model 65
Line
-to-Neutral > 3,500 > 100,000 A > 80,000 A > 65,000 A
Line
-to-Ground > 3,500 > 100,000 A > 80,000 A > 65,000 A
Neutral-to-Ground > 3,500 > 100,000 A > 80,000 A > 65,000 A
Line
-to-Line > 3,500 > 100,000 A > 80,000 A > 65,000 A
P
e
r Phase > 7,000 > 200,000 A > 160,000 A > 130,000 A
Enclosure
NEMA 1 rated.
Surface mount dimensions are 12” x 20” x 6”.
Flush mount unit is 12” x 21.5” x 6”.
W
e
i
ght is 15 lb
s
.
EMI/RFI Noise Rejection Values
Single Unit Frequency System Installation
34 dB
100 kHz 51 dB
51 dB 1 MHz 94 dB
54 dB 10 MHz 114 dB
48 dB 100 MHz 120 dB
H
o
w T
o O
r
der Liebert Liebert PanelGuard
Ex
t
e
nsi
o
n
Duty life cycle tested to survive 20kV, 10kA, IEEE C62.41 Category C3 surge current
with less than 5% degradation of clamping voltage.
All systems EMI-RFI noise or attenuation rejection values are in compliance with test
and evaluation procedures outlined in NEMA LS 1-1992, paragraphs 2.2.11 and 3.11.
P
h
as
e c
o
nfiguration Code
1 P
h, 3W+G
. 12
0
/
240 VAC 120S
3 P
h, 4W+G
. 12
0
/
208 VAC 120Y
3 P
h, 4W+G
. 27
7
/
480 VAC 277Y
Other phase configurations available.
Please consult factory.
kA p
e
r m
od
e/per phase Code
65 kA pe
r mode
, 130 kA pe
r ph
ase 65
80 kA pe
r mode
, 160 kA pe
r ph
ase 80
100 kA pe
r mode
, 200 kA pe
r ph
ase 100
T
rim t
yp
e
Code
Sur
f
ac
e mo
unt trim S
F
lu
sh mo
un
t trim F
M
o
nit
o
rin
g options Code
S
t
and
ar
d S
tatus LEDs only -00
LEDs
, A
u
d
ibl
e Alarm, Counter -01
LEDs
, A
u
d
ibl
e Alarm -02
LEDs
, C
o
un
t
er -03
H
o
w t
o c
onstruct a Liebert PanelGuard
Ex
t
e
nsi
on (LPGE) model # Code
1. Li
e
be
r
t PanelGuard Extension LPGE
2. P
h
a
s
e configuration 120S
3. kA pe
r mod
e
/
per phase 65
4. T
r
im t
y
pe: surface mount S
5. M
onit
or
ing op
tions -01
Sample model #: LPGE120S65S-01
Whi
l
e e
v
e
r
y precaution has been taken to ensure accuracy and
c
om
pl
e
t
e
ne
s
s in this lit
erature, Liebert Corporation assumes no
r
esponsibility, and disclaims all liability for damages resulting
f
r
om u
s
e o
f this information or for any errors or omissions.
© 2008 Liebert Corporation. All rights reserved throughout
the world. Specifications subject to change without notice.
All names referred to are trademarks or registered trademarks
o
f their respective owners.
® Liebert is a registered trademark of the Liebert Corporation.
SL
-22065 (R06/08) Pr
in
ted in USA
B
usiness-Critical Continuity
, Eme
rson Network
P
o
w
e
r an
d the Eme
rson Network Power logo are
trademarks and service marks of Emerson
Electric Co. ©2008 Emerson Electric Co.
800 288 6169 Toll-Free
607 721 8865 Phone
607 722 8713 Fax