Enterasys Networks 4H4203-72 Switch User Manual


 
Connecting to COM Port for Local Management
3-20 Installation
1. VerifythatalinkexistsbycheckingthattheportRXLEDisON(flashingamber,
blinkinggreen,orsolidgreen).IftheRXLEDisOFFandtheTXLEDisnotblinking
amber,performthefollowingstepsuntilitison:
a. Toviewthereceiveandtransmitactivityon
agroupofsegments,pressthe
GROUPSELECTswitch(seeFigure 311)tosteptotheappropriategroup.Each
timetheGROUPSELECTswitchispressed,theGROUPLEDlightsupin
sequence,indicatingwhichGroupisselected.Onthe4H428449,youcanstepto
1,2,3,or
4forGroups1through4.Thereceiveandtransmitactivityforthat
groupofsegmentsisthenindicatedbytheRXandTXLEDsforeachsegment.
b. Ifthereareseparatefiberopticconnectionsontheotherdevice,checkthe
crossoverofthecables.Swapthecableconnectionsifnecessary.
c. Verify
thatthefiberconnectionmeetsthedBlossandcablespecificationsfor
multimodecabling,asoutlinedintheCablingGuide.
Ifalinkisnotestablished,seeChapter 4fortroubleshootinginformationbefore
contactingEnterasysNetworks.TocontactEnterasysNetworks,referto“GettingHelp”
onpage xviiifordetails.
Connecting to COM Port for Local Management
ThissectiondescribeshowtoinstallaUTPstraightthroughcablewithRJ45connectors
andoptionaladapterstoconnectaPC,aVTseriesterminal,oramodemtoan
Enterasys NetworksmoduletoaccessLocalManagement.Thissectionalsoprovidesthe
pinoutassignmentsoftheadapters.
What Is Needed
Thefollowingisalistoftheusersuppliedpartsthatmaybeneededdependingonthe
connection:
•RJ45toDB9femaleadapter
•UTPstraightthroughcablewithRJ45connectors
•RJ45toDB25femaleadapter
•RJ45toDB25maleadapter
WithaUTPstraightthroughcablewithRJ45connectorsandRJ45toDB9
adapter,you
canconnectproductsequippedwithanRJ45COMporttoanIBMorcompatiblePC
runningaVTseriesemulationsoftwarepackage.
Note: The RJ45 COM port connector is located in approximately the same location on all
DFE-Gold modules. In the following procedures, the 4H4282-49 COM port is shown as an
example in the figures associated with each procedure.