ETA-S20
AC Power Distribution Unit & Surge Suppressor
FRONT PANEL FEATURES
1. Unswitched AC Outlet
The120VAC20ANEMA5-20RoutletisalwayslivewhentheETA-S20powercordispluggedintoanACMainspowersourceand
voltage is present. Note: The AC Mains power switch does not affect the Unswitched AC Outlet. The Unswitched Outlet is protected
by the surge protection circuitry.
2. AC Mains Breaker
The120VAC20A2500WratedbreakerwillopenifthecombineddrawofallACoutletsexceeds20A.Note: The breaker is designed to
exceed its rating for a short period of time. If the breaker is tripped, you must first remove the load from the ETA-S20 and then push to
reset.
3. Power Switch
ToturntheETA-S20OnorOff,presstheswitchtotheONorOFFposition.Thisswitchpowersthe“switched”outlets.Theswitch
willilluminateRedwhenitisintheONposition.
4. Power AC Present LED
WillilluminateRedwhentheACMainsPowerSwitchisintheONposition.
5. AC Protect Active LED
Although the Clamping Suppression circuit virtually assures protection from most transient voltage spikes and surges, nature has
a way of occasionally creating electrical forces that are beyond the capabilities of any device to absorb without some degree of
damage.Intherareinstancethatthisoccursandthecircuithasbeendamaged,theGreen“ACProtectActive”LEDindicatorwillturn
Off, indicating that the AC Protect Circuitry is no longer protecting equipment connected to the Switched outlets. The unit will still
operate as an AC distribution unit but the surge suppressor protection will not function until the unit is repaired. Note:Beadvisedthat
activation of this fault condition and the associated repair is not covered under warranty. If the AC Protect is disengaged, it is important
to have all equipment that was connected to that AC Mains Line be inspected for proper operation.
REAR PANEL FEATURES
1. AC Mains Input
Connectthe12gauge9'(2.74m)powercordtoa20A120VACoutlettoprovidepowertotheETA-S20.
2. AC Power Outlets Switched
Seven120VAC20ANEMA5-20Routletsare“Live”whenthefrontpanelpowerswitchisactivated.
3. Unswitched AC Outlet
The120VAC20ANEMA5-20RoutletisalwayslivewhentheETA-S20powercordispluggedintoanACmainspowersourceand
voltage is present. Note: The AC mains power switch does not affect the Unswitched AC Outlet. The Unswitched Outlet is protected
by the surge protection circuitry.
1 2 354
1 32