Unloading a Plate from the Printer | 21
WARNING:
The plate edges are sharp. To avoid injury remove your hand from the plate after you press t
he
Pause/reset button.
8.
Press the Pause/reset button and let go of the plate. The printer loads and aligns the plate in the
correct position.
9. When you see PAPER SETTINGS > ARE THESE SETTINGS OK? on the LED display, be sure to
select
NO PAPER SELECTED.
Note:
Since you will use multiple plates consecutively on the printing press, it is best to load plates into the printer in
the same direction each time. If this is not done, there is a slight possibility of minor differences in final printing.
Unloading a Plate from the Printer
After printing is finished, the plate stays in the printer. To prevent damage to the plate, make sure it
doesn’t fall. Hold the plate and do one of the following:
If you plan to print more plates, press the Paper release (ePlaten) button. The plate currently in
the printer is released and you can load another plate.
If you’re done printing plates, press the d button.
Using the PCU
After a plate is printed and prior to punching or loading it on the press, the plate must be run through the
plate curing unit.
1. Turn on the power switch from the rear of the unit. This activates the transport belt.
Power switch