Extron electronic BB 710M Switch User Manual


 
2
BB 710M • Installation Guide (Cont’d)
New Construction Installation
1. Secure the endplates to the U-plate, using the four provided
screws.
2. Before the drywall has been secured to the studs, place the wall
box in a suitable place so that the tabs on the sides of the box are
flat against a vertical stud.
3. Secure the wall box to the stud (metal or wooden) using two nails
or screws.
4. Run the cable conduits to the box and connect them to one of
the available knock-out holes. Leave enough cable to provide
slack for installing the TouchLink panel.
5. Measure the position of the back box, and mark and cut a hole in
the drywall where the box is placed.
NOTE: The hole is 7.7 inches (19.5 cm) wide x 6 inches
(15.1 cm) high.
6. Secure the drywall to the studs.
NOTE: The tabs of the wall box sit on the stud against the inner face of the drywall.
7. If required, paint the drywall. Insert the cardboard cover (provided) into the back box to avoid getting paint on it.
Mounting the Touchpanel
For complete instructions about installing and calibrating the
TouchLink panel, see the TLP 710MV and TLP 710TV User Guide,
available on the Extron website
(www.extron.com).
1. Connect the cables to the back of the TouchLink panel (see the
user guide). Feed excess cable back into the conduit.
2. Test the connections and configure the TouchLink panel (see
the user guide).
3. Fold the locking arms into their recesses on the side of the
touchpanel and slide the unit into the back box.
4. Tighten the screws on the front of the unit so that the locking
arms rotate into place behind the top and bottom plates of
the back box and hold the unit in place (see figures 4 or 6).
5. Snap the faceplate into position (see figures 4 or 6).
68-2150-01 Rev. B
07 12
Mounting Screws (2)
Extron BB 710M
Wall Box
for Wall-mounting
Extron TLP 710MV
3
Tabs are in contact
with the wall stud.
Figure 5.
Figure 6.
Bezel snaps to unit
(4 places on each side).
Tighten screws to
rotate locking arms.
Tabs are against
outside surface
of wall stud.
Extron Headquarters
+1.800.633.9876 (Inside USA/Canada Only)
Extron USA - West Extron USA - East
+1.714.491.1500 +1.919.850.1000
+1.714.491.1517 FAX +1.919.850.1001 FAX
Extron Europe
+800.3987.6673
(Inside Europe Only)
+31.33.453.4040
+31.33.453.4050 FAX
Extron Asia
+800.7339.8766
(Inside Asia Only)
+65.6383.4400
+65.6383.4664 FAX
Extron Japan
+81.3.3511.7655
+81.3.3511.7656 FAX
Extron China
+4000.398766
Inside China Only
+86.21.3760.1568
+86.21.3760.1566 FAX
Extron Middle East
+971.4.2991800
+971.4.2991880 FAX
Extron Korea
+82.2.3444.1571
+82.2.3444.1575 FAX
Extron India
1800.3070.3777
Inside India Only
+91.80.3055.3777
+91.80.3055.3737 FAX
© 2012 Extron Electronics All rights reserved. www.extron.com