Extron electronic FOX T UWP 302 Switch User Manual


 
Operation
After all devices are connected and powered, the system is fully operational. The
FOX T UWP 302 can be configured through SIS commands (see Simple Instruction Set
Control on page 13) or the FOX Extenders control program (see FOX Extenders Control
Program on page 21).
Initial Power Up
Upon initial power up, all the front panel LEDs blink simultaneously. They blink once to
indicate the device is a multimode device or twice to indicate the device is a singlemode
device. Afterwards, the LEDs return to their normal signal presence indication.
If a different SFP module or no SFP module is connected, the LEDs first blink once or twice
to identify the device and then blink continuously.
System Reset
Use the Reset button beneath the faceplate to return the device to default settings or to
restore factory-shipped firmware (see to the Reset Mode Summary table below for more
details). If necessary, remove the faceplate.
Reset Mode Summary
Mode Mode Activation Result Purpose/Notes
Factory Reset
1 Hold the Reset button down
while applying power to the
device.
NOTE: After a mode 1
reset, update the device
with the latest firmware
version. DO NOT operate
the firmware version that
results from this mode
reset.
• The device reverts to the factory
default firmware.
• All user files and settings (audio
adjustments, audio input selection,
input selection, auto-switch mode,
picture adjustments, and input
video format) are maintained.
Use mode 1 to revert
to factory firmware for
a single power cycle if
an incompatibility issue
arises.
Reset to Factory Defaults
5 Hold the Reset button down
for about 9 seconds or until
the Power LED blinks three
times. Then press the Reset
button momentarily (for
<1 second) within 1 second.
NOTE: The reset
procedure is aborted if the
second momentary press
does not occur within one
second.
• Mode 5 performs a complete
reset to factory defaults except for
firmware.
• Reset all user modifiable
configurations to default values
including real-time adjustments.
• The Power LED blinks 4 times in
quick succession during the reset.
Use mode 5 to start
over with configuration
or uploading.
NOTE: This is
equivalent to SIS
command ZXXX.
FOX T UWP 302 Wallplate Transmitter • Installation and Operation 12