Extron electronic MSW 4V RS Switch User Manual


 
Command and Response Table for SIS Commands
Command ASCII Command
(host to unit)
Response
(unit to host)
Additional Description
Input selection
Select input
X! ! InX!] Selects input (X! 1 to 4)
Input video sensing
Request status of all inputs
0S
Sig
X@
X@
X@
X@]
Each X@ response is the signal status of an
input, from input 1 to 4.
X@ = 0 (no signal) or
1 (signal detected).
Example:
0S
Sig
1
0
0
1]
Input 1 = signal present; input 2 = no signal
present; input 3 = no signal present; input 4
= signal present.
Request the status of an
individual input
X!S X@] Signal status for input X! is X@
Video mute
Mute or unmute video
X#B VmtX#] Toggles between video mute and unmute; X#
= 0 (unmute) or 1 (mute).
Read mute status
B
X#]
Shows mute status.
Mode select
Normal/auto switch mode
X$# FX$]
Toggle between normal and autoswitch
modes.
X$ = 1 (normal) or 2 (auto)
Information Requests
General information
I
V
X%
FX$
VmtX#] For currently selected input X% (1 to 4)
switcher is in
X$ mode (1 = normal, 2 = auto)
and video mute status is
X# (0 = unmute, 1
= mute).
Example:
I
V2
F1
Vmt0]
Video is selected on input 2; switcher is in
normal mode (F1); video mute is off.
Query firmware version
Q
x.xx
]
View the rmware version.
Query part number
N
60-480-xx
]
View the part number (60-480-11 or
60-480-12).
Upload rmware
EUpload} Go]
Upload rmware.
System reset (factory default)
EZxxx Zpx]
Resets unit to factory defaults.
MSW 4V rs and MSW 4SV rs • SIS Commands 19