Extron electronic MSW 4V Switch User Manual


 
VersaTools
®
MSW 4V & 4SV • Installation and Connections
VersaTools
®
MSW 4V & 4SV • Installation
VersaTools
®
MSW 4V & 4SV, cont’d
Do not tin the power supply leads before installing the
captive screw connector. Tinned wires are not as secure
in the captive screw connectors and could be pulled out.
To verify the polarity before connection, plug in the power
supply with no load and check the output with a voltmeter.
The two power cord wires must be kept separate
while the power supply is plugged in. Remove
power before wiring.
Alternately, an Extron P/S 100 Universal 12 VDC Power Supply,
part #60-357-01, can power up to ten MSWs or other Extron
12 VDC devices using only one AC power connector.
Front Panel Controls and Indicators
Figure 9 shows the front panels of the MSW 4V and MSW 4SV.
A/V SWITCHER
MODE NORMAL
AUTO
AUTO
SWITCH
1
2
3
4
12
7
8
9 10 11
Figure 9 — MSW 4V and MSW 4SV front panel
Input selection
7
Input 1 through 4 buttons — Each Input button selects the
associated input for output.
The Input 1, Input 2, and Input 3 buttons are also used to toggle
auto-switch mode on and off. See Auto switch mode controls and
indicators and items
9
,
10
, and
11
.
8
Input 1 through 4 LEDs — The Input LEDs identify the selected
input.
VersaTools
®
MSW 4V & 4SV • Controls and Indicators8
Autoswitch mode controls and indicators
9
Mode button — The Mode button is used with the Normal
button or the Auto button to select the switching mode. Mode
is a secondary function of the Input 1 button. See Mode selection,
below.
10
Normal button — The Normal button is used with the Mode
button to select normal mode. Normal is a secondary function
of the Input 2 button.
11
Auto(switch) button — The Auto button is used with the Mode
button to select autoswitching mode. Auto is a secondary
function of the Input 3 button.
12
Auto Switch LED — When lit, the Auto Switch LED indicates
that the switcher is in autoswitch mode. The MSW
automatically switches to the highest numbered input with
active sync pulses. When unlit, the switch is in normal
(manual) mode.
Mode selection
Turn autoswitch mode on or off as follows:
1. Press and hold the Mode (Input 1) button.
2a. To select autoswitch mode — Press and release the Auto
(Input 3) button. The Auto Switch Mode Active LED lights.
2b. To select normal mode — Press and release the Normal
(Input 2) button. The Auto Switch Mode Active LED goes
off.
3. Release the Mode button.
9VersaTools
®
MSW 4V & 4SV • Controls and Indicators