Extron electronic XTP PI 400 Switch User Manual


 
2
XTP PI 400 Power Injector • Setup Guide (Continued)
Features
Indicators
a
Front panel power LED indicator — Lights to indicate the XTP PI 400 is receiving
power.
b
Front panel XTP Power Out LED indicators — Light when the XTP PI 400 is
providing power to XTP endpoints.
NOTE: If the last connected endpoint draws more power than the XTP PI 400
can provide, the corresponding XTP Power Out LED indicator blinks, indicating
the output cannot be powered because too much power is being drawn from
the XTP PI 400. Disconnect the endpoint to correct the issue.
c
Rear panel Pwr LED indicators — Light or blink to indicate various power states
of the connected endpoints (see the table below for LED states).
LED State Port Status
Unlit The endpoint is not connected or cannot be powered.
Lit The endpoint is receiving power from the XTP PI 400.
Blinks ve times There is a power overload fault.
Blinks nine times The power allocation is exceeded.
NOTE: Blinking LEDs repeat the number of blinks specified in the table above after a short interval of remaining unlit.
Twisted Pair Cable Termination and Recommendations
Use the following pin conguration for twisted pair cables.
TIA/EIA T568B
Pin Wire Color
1 White-orange
2 Orange
3 White-green
4 Blue
5 White-blue
6 Green
7 White-brown
8 Brown
Figure 3. Twisted Pair Cable Configuration
Supported cables
The XTP PI 400 is compatible with CAT 5e, 6, 6a, and 7 shielded twisted pair (F/UTP, SF/UTP, and S/FTP) and unshielded twisted
pair (U/UTP) cable.
ATTENTION:
Do not use Extron UTP23SF-4 Enhanced Skew-Free AV UTP cable or STP201 cable.
To ensure FCC Class A and CE compliance, STP cables and STP connectors are required.
Cable recommendations
Extron recommends using the following practices to achieve full transmission distances up to 330 feet (100 m) and reduce
transmission errors.
z Use the following Extron XTP DTP 24 SF/UTP cables and connectors for the best performance:
z XTP DTP 24/1000 Non-plenum 1000 feet (305 m) spool 22-236-03
z XTP DTP 24P/1000 Plenum 1000 feet (305 m) spool 22-235-03
z XTP DTP 24 Plug Package of 10 101-005-02
z If you are not using XTP DTP 24 cable, at a minimum Extron recommends 24 AWG, solid conductor, STP cable with a
minimum bandwidth of 400 MHz.
12345678
RJ-45
Connector
Insert Twisted
Pair Wires
Pins:
Pin
1
2
3
4
5
6
7
8
Wire color
White-green
Green
White-orange
Blue
White-blue
Orange
White-brown
Brown
Wire color
T568A T568B
White-orange
Orange
White-green
Blue
White-blue
Green
White-brown
Brown
1
XTP POWER OUT
XTP PI 400
XTP POWER INJECTOR
2 3 4
Front Panel
ab
XTP
PWR
XTP PWR
c