Falcon SG2K-2T-HW Power Supply User Manual


 
SG Series
TM
UPS PLUS
®
2kVA & 3kVA
24
Electrical Input
Nominal AC Voltage
120V
230V
120V
230V
230V
AC Voltage Range
87 – 140V
170 – 275V
87 – 140V
170 – 275V
170 – 275V
Current – Amps
14.2
7.4
21.4
11.2
7.5
11.3
Frequency
50/60 Hz ± 5% (Auto – Tracking)
Power Factor Correction
> 0.95
Efficiency (Typical)
> 86%
> 85%
Electrical Output
Watts
1400
2100
1400
2100
AC Voltage
(Switchable)
100V
110V
115V
120V
200V
220V
230V
240V
100V
110V
115V
120V
200V
220V
230V
240V
120V
1
(700W
split-
phase,
each
5-20R)
208V
220V
230V
240V
120V
2
1050W
split-
phase,
each
5-20R)
208V
220V
230V
240V
Frequency
50/60 Hz (Auto Tracking )
Frequency Stabi lity
± 0.3% (Battery Mode)
Voltage Regulation
± 2%
± 5%
± 3%
Step Load Change
± 7% for 100% load variation
Harmonic Distortion
< 3% Linear Load, < 5% Non -Linear Load
Overload
105% load for 50 Seconds
Crest Ratio
3:1
Battery
DC Voltage
72V
96V
Type
12V, 7AH Sealed Lead Acid Maintenance -Free
Back Up Time @ Full Load
@ 1/2 Load
7 Minutes
20 Minutes
5.5 Minutes
15 Minutes
7 Minutes
20 Minutes
5.5 Minutes
15 Minutes
Recharge Time
8 Hours to 90%
Battery times are approximate.
Transfer Time
Line Fails/Recovers
Zero
UPS to Bypass or Reverse
< 4ms
After Overload
Auto Transfer to UPS
Electrical Connections
Input - T Models
6’ Cord with
5-20P
6’ Cord with
6-20P, L6-20P
or Schuko
6’ Cord with
L5-30P
6’ Cord with
6-20P, L6-20P
or Schuko
6’ Cord with 6 -20P, L6-20P
or Schuko
-HW Models
Hardwire
Hardwire Not Available
Output -T Models
(6) 5-15R or
(3) 5-15R &
(2) 5-20R
(6) IEC 320
or (1) L6-20R
(6) 5-15R or
(3) 5-15R &
(2) 5-20R
(6) IEC 320
or (1) L6-20R
(2) 5-20R & (1) L6 -20R
-HW Models
Hardwire
Hardwire Not Available
Contact the factory for other input/output options.
Environmental
Operating Temper ature
0º C - 40º C (32º F to 104º F)
Humidity
10% to 95% Non – Condensing
Altitude
7,000 Feet
Cooling
Low Velocity Forced Air Fans
Audible Noise @ 1 Meter
<50dBA
Controls and Indicators
LED
Line, Inverter, Battery Reserve, Load, Bypass, Alarm, Crest , Battery & Load Capacity Level
Audible Alarms
DC Mode, Low Battery, Over/Under Voltage, Over/Under Frequency, High Temp., Over Load, Fault Alarm
Communications
RS-232 Serial Port (Bundled UPSilon 2000 Software)
Mechanical
Dimensions H x W x D inch es (mm)
13.8 x 7.6 x 18.9 (350 x 193 x 480)
13.8 x 7.6 x 30 .0 (350 x 193 x 720)
Weight lb. (kg)
68.4 (31)
81.4 (37)
150.0 (68)
Agency Listing
-1T Models: UL 1778, CUL, FCC Class A -HW Models: UL 1778 & CUL pending
-2T Models (except –HW models): UL 1778, CUL, CE
available with Schuko plug only
Available Options
Option A
60 Hz to 50 Hz Frequency Conversion
Option B
50 Hz to 60 Hz Frequency Conversion
Option C
SNMP/HTTP Network Card (Internal)
Option D
Standard Contact Closure Interface Card
Maintenance Bypass
Make-Before-Break External Wrap Around
External Battery Packs
Extended Run Time Battery Packs (minutes to hours)
Fast Battery Charger
Fast Charger internal to the Extended Battery Pack Cabin et (Required for battery times 2 hours or more.)
Model Number
SG2K-1T
SG2K-1T-HW
SG2K-2T
SG2K-2T-HW
SG3K-1T
SG3K-1T-HW
SG3K-2T
SG3K-2T-HW
SG2K-2TX
SG2K-2TXI
1
SG3K-2TX
SG3K-2TXI
2
Nominal VA
2000
3000
2000
3000