FieldServer FS-8700-86 Computer Drive User Manual


 
FS-8700-86 Carrier DataPort Page 25 of 32
FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web: www.fieldserver.com
Tel: (408) 262 2299 Fax: (408) 262 2269 Toll Free: (888) 509 1970 email: support@fieldserver.com
[CR]oilpmp_b 0 000 000 Cir B, Oil Pump Output [CR]refb_iso 0 000 000 Cir B Refrig Isolate Out[CR] 0 000 000 [CR] 0 000 000 FANS
OUTPUT [CR]fan_b1 0 000 000 Fan Output DO # 1 [CR]fan_b2 0 000 000 Fan Output DO # 2 [CR]fan_b3 0 000 000 Fan Output DO # 3
[CR]fan_b4 0 000 000 Fan Output DO # 4 [CR]fan_b5 0 000 000 Fan Output DO # 5 [CR]fan_b6 0 000 000 Fan Output DO # 6 [CR]fan_b7 0
000 000 Fan Output DO # 7 [CR]fan_b8 0 000 000 Fan Output DO # 8 [CR]FAN_ST_B 0 000 000 Fan Staging Number [CR] 0 000 000 UNIT
DISCRETE IN [CR]onoff_sw 0 000 000 Remote On/Off Switch [CR]hc_sw 0 000 000 Remote Heat/Cool Switch [CR]recl_sw 0 000 000 Remote Reclaim
Switch [CR]sept_sw 0 000 000 Remote Setpoint Switch [CR]limit_sw 0 000 000 Limit Switch Status [CR]lock_1 0 000 000 Interlock Status [CR]pump_def 0
000 000 Pump Run Status [CR]condflow 0 000 000 Condenser Flow Status [CR]elec_box 1 000 000 Electrical Box Safety Sw[CR] 0 000 000
[CR] 0 000 000 UNIT DISCRETE OUT [CR]CLPUMP_1 0 000 000 Cooler Pump #1 Command [CR]CLPUMP_2 0 000 000 Cooler Pump #2 Command
[CR]ROT_PUMP 0 000 000 Rotate Pumps Now [CR]COND_PMP 0 000 000 Condenser Pump Command [CR]COOLHEAT 0 000 000 Cooler Heater Command
[CR]SAFE_ALM 0 000 000 Critical Alarm Signal [CR] 0 000 000 [CR] 0 000 000 UNIT ANALOG [CR]COOL_EWT 48.0 001 000
Cooler Entering Fluid [CR]COOL_LWT 47.7 001 000 Cooler Leaving Fluid [CR]COND_EWT 0.0 001 000 Condenser Entering Fluid[CR]COND_LWT 0.0 001 000
Condenser Leaving Fluid [CR]CHWSTEMP -40.7 001 000 CHWS Temperature [CR]EXT_VDC 0.0 010 000 External 0-10 Vdc Signal[CR]COND_SP 104.0 001 000
Current Cond Setpoint [CR]tot_curr 0 047 000 Chiller Total Current [CR] 0 000 000 RECLAIM ANALOG PARAM [CR]HR_EWT 0.0 001 000 Reclaim
Entering Fluid [CR]HR_LWT 0.0 001 000 Reclaim Leaving Fluid [CR]hr_sp 104.0 001 000 Reclaim Fluid Setpoint [CR]sct_a_sp 118.4 001 000 Cir A SCT Control Point
[CR]sct_b_sp 118.4 001 000 Cir B SCT Control Point [CR]pmpd_p_a 0.0 020 000 Cir A Pumpdown Pressure [CR]pmpd_p_b 0.0 020 000 Cir B Pumpdown Pressure
[CR]hr_v_pos 20.0 003 000 HR Cond Valve Position [CR] 0 000 000 [CR] 0 000 000 RECLAIM DISCRETE PARAM [CR]RECL_SEL 0
000 000 Heat Reclaim Select [CR]condflow 0 000 000 Condenser Flow Status [CR]hr_val_a 0 000 000 Cir A Reclaim Valve Stat[CR]hr_val_b 0 000 000 Cir B
Reclaim Valve Stat[CR]pd_val_a 0 000 000 A Pumpdown Valve Status [CR]pd_val_b 0 000 000 B Pumpdown Valve Status [CR]hrstat_a 0 000 000 Circuit A Reclaim
Status[CR]hrstat_b 0 000 000 Circuit B Reclaim Status[CR]cond_htr 1 000 000 Reclaim Condenser Heater[CR] 0 000 000 OPERATING MODES
[CR]Mode[07] 0 000 000 Startup Delay in effect [CR]Mode[08] 0 000 000 Second Setpoint in Use [CR]Mode[09] 0 000 000 Reset in Effect [CR]Mode[10] 0
000 000 Demand Limit Active [CR]Mode[11] 0 000 000 Ramp Loading Active [CR]Mode[12] 0 000 000 Low Source Protection [CR]Mode[13] 0 000 000 Low
Cooler Suction Cir A[CR]Mode[14] 0 000 000 Low Cooler Suction Cir B[CR]Mode[15] 0 000 000 Low Dis Superheat Cir A[CR]Mode[16] 0 000 000 Low Dis Superheat
Cir B[CR]Mode[17] 0 000 000 High Pres Override Cir A[CR]Mode[18] 0 000 000 High Pres Override Cir B[CR]Mode[19] 0 000 000 High Current Over Cir A
[CR]Mode[20] 0 000 000 High Current Over Cir B [CR]Mode[21] 0 000 000 Reclaim Active? [CR]Mode[22] 0 000 000 Cooler Heater Active? [CR]Mode[23] 0
000 000 Cooler Pumps Rotation? [CR]Mode[24] 0 000 000 Pump Periodic Start? [CR]Mode[25] 0 000 000 Night Capacity Active? [CR]Mode[26] 0 000 000 System
Manager Active? [CR]Mode[27] 0 000 000 Master Slave Active? [CR][CR]
//only 1st line is used