FTLX1341E2 Product Specification – October 2008
© Finisar Corporation – October 2008 Rev B Page 8
Environmental Performance
Operating case temperature: 0°C to +70°C
Operating humidity: 0% -95% RH non-condensing
Fibers and Connectors
The transponder has SC receptacles for both Tx and Rx. The transponder is designed for multimode
SC cables, 0° polished endface (PC).
70-pin Connector
The module interface connector is a 70-pin, printed circuit board edge connection with a 0.5 mm
pitch. The appropriate mating connector for the customer PCB is a 70-pin SMT, dual row, right
angled, edge connector, 0.5 mm pitch (Tyco Electronics part number 1367337-1, Molex part number
74441-0003 or equivalent).
Rail Requirement
The X2 rail system required to mount the X2 module is fully defined by the MSA.
(Tyco Electronics part number 1367608-1: designed for belly to belly applications;
and 1367610-1, designed for single sided board mount to fit into the standard host PCB
footprint; or equivalent). For further details please refer to vendor-supplied information.
Aqueous Wash
Finisar X2 transponders are neither solderable nor aqueous washable and are not
intended for these processes.
VI. Regulatory Compliance
Feature Standard Comments
ESD:
Electrostatic Discharge to the
Electrical Pins (HBM)
EIA/JESD22-A114-B
(MIL-STD 883D
Method 3015.7)
Class 1a (> 500 V)
Immunity:
Against Electrostatic Discharge
(ESD) to the Module Receptacle
EN 61000-4-2
IEC 61000-4-2
Discharges ranging from
±2 kV to ±25 kV to the
front end / faceplate / receptacle cause no damage
to module (under recommended conditions).
Immunity:
Against Radio Frequency
Electromagnetic Field
EN 61000-4-3
IEC 61000-4-3
With field strength of 10 V/m, noise frequency
ranges from 10 MHz to 2 GHz. No effect on
module performance between the specification
limits.
Emission:
Electromagnetic Interference
(EMI)
FCC 47 CFR
Part 15, Class B
EN 55022 Class B
CISPR 22
Noise frequency range:
30 MHz to 40 GHz
Radiated emission does not exceed specified
limits when measured with module inside a
shielding enclosure with a MSA conforming
cutout.