Fujitsu MAP3735NC/NP Computer Drive User Manual


 
C141-E166 5-7
Table 5.1 SCSI ID setting (CN2 on NP model only)
SCSI ID CN2
7-8 5-6 3-4 1-2
0 Open Open Open Open
1 Open Open Open Short
2 Open Open Short Open
3 Open Open Short Short
4 Open Short Open Open
5 Open Short Open Short
6 Open Short Short Open
7 Open Short Short Short
8 Short Open Open Open
9 Short Open Open Short
10 Short Open Short Open
11 Short Open Short Short
12 Short Short Open Open
13 Short Short Open Short
14 Short Short Short Open
15 (*1) Short Short Short Short
*1 Set at factory shipment
IMPORTANT
1. Set the SCSI ID so that there are no duplicates between SCSI devices on
the same SCSI bus.
2. The priority of SCSI bus use in ARBITRATION phase is determined by
SCSI ID as follows:
7 > 6 > 5 > 4 > 3 > 2 > 1 > 0 > 15 > 14 > 13 > 12 > 11 > 10 > 9 > 8
5.3.2 Each mode setting (NP model only)
(1) Setting terminator power supply
Refer to Table 5.2 for controlling the supply of power from the drive to the SCSI terminator power
source (TERMPOW). For information on NP model, refer to Figures 5.2 and 5.3.
Table 5.2 Setting SCSI terminator power supply (NP model only)
Supply on/off of SCSI terminator power from IDD CN2 23-24
Supply off Open
Supply on Short
(default)
(default)