4.2 Log Parameters
C141-E167 4 - 57
4.2.11 SMART status page (X'2F')
[Fujitsu unique page]
Bit
Byte
76543210
0 00101111
1 X‘00’ (Reserved)
2 Page Length (MSB)
3 Page Length (LSB)
4
SMART Status Parameter
n
This page contains parameters which allow the application client to check the predictive drive failure
condition of the IDD. The application client can check whether the IDD has predicted a drive failure
by periodically reading out this page.
The "Page Length" field indicates the length (byte length) after byte 4.
The "SMART Status Parameter" field is Fujitsu unique parameters. The details of this field are
outside the scope of this manual.
4.2.12 SMART data page (X'38')
[Fujitsu unique page]
Bit
Byte
76543210
0 00111000
1 X‘00’ (Reserved)
2 Page Length (MSB)
3 Page Length (LSB)
4
Log Parameters
n
This page reports data which the IDD collects for predicting drive failures.
The "Page Length" field indicates the length (byte length) after byte 4.
The "Log Parameters" field is Fujitsu unique parameters. The details of this field are outside the
scope of this manual.
~
~
~
~
~
~
~
~
~
~
~
~