Fujitsu MAX3036RC Computer Drive User Manual


 
5.4 Checking Operation after Installation and Preparing the HDDs for Use
C141-E237 5-9
(2) Caching parameters
The following parameters are used to optimize HDD Read-Ahead caching operations under the
system environments. Refer to Chapter 3 “Data Buffer Management” of the Interface Specifications
for further details.
Parameter Default value
• IC: Initiator control 0 (Drive-specific
control (page
cache))
• RCD: Disabling Read-Ahead caching operations 0 (enabled)
• WCE: Write Cache Enable 1 (enabled)
• MS: Specifying the multipliers of "minimum
prefetch" and "maximum prefetch" parameters
0 (Specifying
absolute value)
• DISC: Prefetch operation after track switching during
prefetching
1 (enabled)
• Number of blocks for which prefetch is suppressed X'FFFF'
• Minimum prefetch X'0000'
• Maximum prefetch X' XXXX'
(1 cache segment)
• Number of blocks with maximum prefetch restrictions X'FFFF'
• Number of segments X'08'
Notes:
1. When Read-Ahead caching operations are disabled by the caching parameter, these
parameter settings have no meaning except write cache feature.
2. Determine the parameters in consideration of how the system accesses the disk. When the
access form is not determined uniquely because of the processing method, the parameters
can be re-set actively.
3. For sequential access, the effective access rate can be increased by enabling Read-Ahead
caching operations and Write Cache feature.
(3) Control mode parameters
The following parameters are used to control the tagged queuing and error logging.
a. Control mode parameters
Parameter Default value
• Queue algorithm modifier 0 (Execution sequence of
read/write commands is
optimized.)
• QErr: Resume or abort remaining suspended
commands after sense pending state
0 (command is resumed)
• DQue: Disabling tagged command queuing 0 (enabled)