Fujitsu MAY2073RC Computer Drive User Manual


 
Error Analysis
7-4 C141-E230
7.2.2 Sense data (3-0C-03), (4-32-01), (4-40-xx), (4-C4-xx), and (4-44-xx)
Sense data (3-0C-03), (4-32-01), (4-40-xx), (4-C4-xx), and (4-44-xx) indicate one of the following:
A target sector could not be detected using the sector counter.
A seek process overran the specified time.
A write to a disk terminated abnormally.
An error occurred in power-on self-diagnosis.
A drive error occurred.
The symptoms above are generally caused by an error in a PCA or DE.
7.2.3 Sense data (1-1x-xx), (3-1x-xx) and (E-1D-00): Disk read error
If sense data (1-1x-xx), (3-1x-xx) or (E-1D-00) occurs frequently in a specific block of a disk, there
is disk damage that was not recorded in the media defect list. In this case, assign an alternate block
to the error-detected block using a REASSIGN BLOCKS command. For an explanation of the
REASSIGN BLOCKS command, refer to Subsection 4.3.2 “REASSIGN BLOCKS (07)” of the
Interface Specifications.
If this error occurs in different blocks, a PCA or DE is faulty.
7.2.4 Sense data (5-2x-xx), (B-44-xx), (B-47-xx), (B-4B-xx) and (B-4E-00): interface error
Sense data (5-2x-xx), (B-44-xx), (B-47-xx), (B-4B-xx) and (B-4E-00) indicate one of the following
symptoms:
An invalid or unsupported command was issued, or invalid or unsupported parameters were
specified.
An interface error occurred.
A hardware error occurred inside HDDs.
If this error occurs, the PCA or the interface is faulty.