Fujitsu MBA3147NC Computer Drive User Manual


 
Use four holes (No.1 to No.4) to mount.
Holes for
mounting screw
1
2
3
4
In case of using a
center hole, use it in
combination with the
holes of both ends.
Holes for mounting screw
Figure 4.5 Limitation of side-mounting
(4) Limitation of bottom-mounting
Use all four mounting holes on the bottom face.
(5) Environmental temperature
Temperature condition at installed in a cabinet is indicated with ambient temperature measured
30 mm from the disk drive. At designing the system cabinet, consider following points.
Make a suitable air flow so that the DE surface temperature never exceed 60°C.
Cool the PCBA side especially with air circulation inside the cabinet. Confirm the cooling
effect by measuring the surface temperature of specific ICs and the DE. These measurement
results must satisfy the temperature condition listed in Table 4.1.
Keep the DE surface temperature at 50 °C or below to meet the condition for assuring an
MTBF of 1,400,000 hours. An air flow of 0.9 m/s or more is required at ambient temperature
30 °C.
Table 4.1 Surface temperature check point
No. Measurement point
Max. temperature on
package
1 DE surface 60 °C
2 Read channel LSI 82 °C
3 VCM/SPM Driver 100 °C
4 HDC 100 °C
5 MPU 94 °C
52 C141-E270