CNH2 (EXTERNAL SWITCH
SETTING)
Device Driver
You need to install Fujitsu's device driver to avoid the 2KB sector
problem in Windows9x and the OS-timeout-problem in Windows9x and
NT3.51/4.0.
MCD3130SS HANDLING AND MAINTENANCE
WORLD WIDE WEB SITE
Corporate
http://www.fujitsu.co.jp/
SINGAPORE
http://www.fujitsu-computers.com.sg/
USA
http://www.fcpa.com/
CANADA
http://www.fujitsu.ca/
EUROPE
http://www.fujitsu-europe.com/
AUSTRALIA
http://www.fujitsu.com.au/
Orientation
The drive can be installed in one
of three orientations; either PCA
up or on either side edge.
Ejecting cartridge
Cartridges can be ejected by
pressing the eject key or by a
SCSI eject command. Never
eject a cartridge mechanically
except in an emergency.
Cleaning lens and media
recommendation
Clean the lens on the drive head
and the disk media once every
three months. More frequent
cleaning may be required in a
dirty environment. Use the
Fujitsu head cleaning kit and
media cleaning kit. Head
Cleaning kits from other vendors
will not work.
1
2
3
4
6
5
7
8
9
10
11
12
13
14
15
16
0V
TTL-IC
OPERATOR PANEL
Note: The cable length must not exceed 30cm.
This guide is prepared to instruct the user on the switch and jumper
settings in the MCD3130SS when you install your MCD3130SS.
Note; Factory default settings are marked with
✻.
Layout of PCA SCSI ID Setting
SW1 AND CNH2 SETTINGS
Switch 1 sets the SCSI ID and some drive functions and CNH2 sets
additional drive functions.
SW1
CNH1 (TERMINATING POWER AND SCSI TERMINATION)
Terminal CNH1 uses shorting bars to set the power source and to
enable or disable SCSI termination.
Key# Function Key on Key off
01 ✻
02 SCSI ID (see table 1 above)
———— ————
✻
03 ✻
04 SCSI data bus parity check Enabled ✻ Disabled
05 Write cache mode Enabled Disabled ✻
06 Device type mode MO ✻ Fixed Disk
07 Spindle automatic stop mode
Enabled Disabled
✻
08 Factory test (Not to be set by user) Enabled Disabled ✻
SCSI ID SW1-01 SW1-02 SW1-03
0 ✻ Off Off Off
1 Off Off On
2 Off On Off
3 Off On On
4 On Off Off
5 On Off On
6 On On Off
7OnOnOn
Table 1
MCD3130SS
Magneto-Optical Disk Drive
Installation Guide
Installationsanleitung
Guide d'installation
COPYRIGHT FUJITSU LIMITED
JAN. 1999 C156-E096-01XA
Pin# Function Open Short
1 Cartridge-in detection
——
2 SCSI ID 4
——
3 LED source (+5 V)
——
4 SCSI ID2
——
5 LED source (–)
——
6 SCSI ID1
——
7 Signal to eject cartridge
——
8 Ground
——
9 Device type mode Fixed disk MO
10
SCAM mode Disabled Enabled
11 Write verify mode
Enabled Disabled
12 Ground
——
13 Macintosh mode Disabled
Enabled
14 SCSI type 0 SCSI 2 SCSI 1
15 Terminating resister mode
Disabled Enabled
16 Ground
——
Not
used
GND
+5V
DC
SCSI
Pin 50
SCSI
Pin 2
Pin# Function Short Open
1–2 Power supplied by Supplied Not
drive supplied
3–4 Power supplied by Supplied Not
host controller supplied
5–6 SCSI termination Enabled Disabled
enabled
Power supplied by 1–2 3–4
Drive Short Open
Host controller Open Short
Drive and Host Short Short
controller