Fujitsu MHM2100AT Computer Drive User Manual


 
Interface
5-50 C141-E104-02EN
The READ NATIVE MAX ADDRESS command is not executed just before this
command. The command is the SET MAX ADDRESS command if it is the
command just after the READ NATIVE MAX ADDRESS command is executed.
At command issuance (I/O registers setting contents)
1F7
H
(CM)11111001
1F6
H
(DH) x x x DV xx
1F5
H
(CH)
1F4
H
(CL)
1F3
H
(SN)
xx
xx
xx
1F2
H
(SC) xx
1F1
H
(FR) 04
At command completion (I/O registers contents to be read)
1F7
H
(ST) Status information
1F6
H
(DH)
1F5
H
(CH)
1F4
H
(CL)
1F3
H
(SN)
1F2
H
(SC)
xx
xx
xx
xx
xx
1F1
H
(ER) Error information
(17) READ NATIVE MAX ADDRESS (F8)
This command posts the maximum address intrinsic to the device, which can be
set by the SET MAX ADDRESS command. Upon receipt of this command, the
device sets the BSY bit and indicates the maximum address in the DH, CH, CL
and SN registers. Then, it clears BSY and generates an interrupt.