Interface
5-80 C141-E120-02EN
•
SECURITY ERASE UNIT
FROZEN MODE is canceled when the power is turned off, or when hardware is
reseted. If this command is reissued in FROZEN MODE, the command is
completed and FROZEN MODE remains unchanged.
Issuing this command during LOCKED MODE returns the Aborted Command
error.
The following medium access commands return the Aborted Command error
when the device is in LOCKED MODE:
•
READ DMA •
WRITE DMA •
SECURITY DISABLE PASSWORD
•
READ LONG •
WRITE LONG •
SECURITY FREEZE LOCK
•
READ MULTIPLE •
WRITE MULTIPLE •
SECURITY SET PASSWORD
•
READ SECTORS •
WRITE SECTORS •
SET MAX
•
READ VERIFY
SECTORS
•
WRITE VERIFY •
FLUSH CACHE
At command issuance (I-O register contents)
1F7
h
(CM) 11110101
1F6
h
(DH) x x x DV xx
1F5
h
(CH)
1F4
h
(CL)
1F3
h
(SN)
1F2
h
(SC)
1F1
h
(FR)
xx
xx
xx
xx
xx
At command completion (I-O register contents)
1F7
h
(ST) Status information
1F6
h
(DH) x x x DV xx
1F5
h
(CH)
1F4
h
(CL)
1F3
h
(SN)
1F2
h
(SC)
1F1
h
(ER)
xx
xx
xx
xx
Error information