Fujitsu MHT2040AT Computer Drive User Manual


 
Interface
5-56 C141-E192-01EN
Table 5.6 Diagnostic code
Code Result of diagnostic
X’01’
X’02’
X’03’
X’04’
X’05’
X’06’
X’8x’
No error detected.
HDC diagnostic error
Data buffer diagnostic error
Memory diagnostic error
Reading the system area is abnormal
Calibration abnormal
Failure of device 1
attention: The device responds to this command with the result of power-on
diagnostic test.
At command issuance (I/O registers setting contents)
1F7
H
(CM)10010000
1F6
H
(DH) x x x DV
Head No. /LBA [MSB]
1F5
H
(CH)
1F4
H
(CL)
1F3
H
(SN)
1F2
H
(SC)
1F1
H
(FR)
xx
xx
xx
xx
xx
At command completion (I/O registers contents to be read)
1F7
H
(ST) Status information
1F6
H
(DH) x x x DV
Head No. /LBA [MSB]
1F5
H
(CH)
1F4
H
(CL)
1F3
H
(SN)
1F2
H
(SC)
1F1
H
(ER)
xx
xx
01
H
01
H
Diagnostic code