Fujitsu MHW2060AC Computer Drive User Manual


 
5.3 Host Commands
(38) READ DMA EXT (X’25’): Option (customizing)
Description
This command is the extended command of the READ DMA command. The LBA
specification is increased from 28 bits to 48 bits, and the maximum number of
sectors that can be transferred by a single command is changed from 100h to
10000h. Other command controls are the same as those of the READ DMA
command.
At command issuance (I/O registers setting contents)
1F7
h
(CM) 0 0 1 0 0 1 0 1
1F6
h
(DH) 1 L 1 DV xx
1F5
h
(CH) P
1F5
h
(CH) C
1F4
h
(CL) P
1F4
h
(CL) C
1F3
h
(SN) P
1F3
h
(SN) C
1F2
h
(SC) P
1F2
h
(SC) C
1F1
h
(FR) P
1F1
h
(FR) C
LBA (47-40)
LBA (23-16)
LBA (39-32)
LBA (15-8)
LBA (31-24)
LBA (7-0)
Sector count (15-8)
Sector count (7-0)
xx
xx
C: Current
P: Previous
At command completion (I/O registers contents to be read)
1F7
h
(ST) Status information
h
( 1 L 1 DV xx
1F5
h
(CH) 1
1F5
h
(CH) 0
1F4
h
(CL) 1
1F4
h
(CL) 0
1F3
h
(SN) 1
1F3
h
(SN) 0
1F2
h
(SC) 1
1F2
h
(SC) 0
1F1
h
(ER)
LBA (47-40)
LBA (23-16)
LBA (39-32)
LBA (15-8)
LBA (31-24)
LBA (7-0)
xx
xx
Error information
1F6 DH)
0: HOB=0
1: HOB=1
C141-E258 5-111