Interface
5-46 C141-E262
(10) STANDBY IMMEDIATE (X '94' or X 'E0')
Upon receipt of this command, the device enters the standby mode. The device
then reports the status to the host system. This command does not support the
APS timer function.
• Error reporting conditions
(1) A SATA communication error occurred (ST = 51h, ER = 14h).
At command issuance (Shadow Block Registers setting contents)
CM X '94' or X 'E0'
DH x x x x Xx
CH
CL
SN
SC
FR
xx
xx
xx
xx
Xx
At command completion (Shadow Block Registers contents to be read)
ST Status information
DH x x x x Xx
CH
CL
SN
SC
ER
xx
xx
xx
xx
Error information