Furman Sound AC-210 E Power Supply User Manual


 
Furman Sound, Inc.
1997 South McDowell Blvd.
Petaluma, California 94954-6919 USA
Phone: 707-763-1010
Fax: 707-763-1310
Web: www.furmansound.com
E-mail: info@furmansound.com
040105-D
Specifi cations
AC Current Capacity
Input:
15 Amp capacity required (10 Amp for the AC-210 E)
Output:
15 Amp RMS (both outlets combined) (10 Amp for the
AC-210 E)
AC Noise Attenuation
Transverse (Differential) Mode
>40dB from 10kHz to 100kHz
>80dB from 100kHz to 1GHz
(linear attenuation curve from 0.05 to 100Ω line impedance)
Transient Voltage Surge
120VAC (230VAC for AC-210 E)
Suppression
Series Multi-Stage Protection Plus Non-Sacrifi cial
with Zero Ground contamination
Domestic:
188V peak clamping @ 6000V/3000A input
International:
276V peak clamping for AC-210 E
Extreme Voltage Shutdown
137 VAC typically
(270 VAC typically for the AC-210 E)
(260 VAC typically for the AC-210 E UK)
Dimensions & Weight
1.75” (H) x 5” (W) x 8.5” (D), 3 lbs.
Safety Agency Listing
CE / TUV / NRTL-C