Furuno FELCOM 500 Network Router User Manual


 
1. HOW TO INSTALL THE UNIT
12
1.2 Communication Unit
Select a location for the communication unit (CU) by following the information shown below.
The unit is not waterproof. Keep the unit away from water splash.
Keep the unit away from direct sunlight.
The temperature and humidity must meet the requirements shown in the equipment specifica-
tions.
Set the unit away from the exhaust pipes and vents.
The installation location must have enough cool air.
Install the unit where shock and vibration meet the requirements shown in the equipment spec-
ifications.
Keep the unit away from the equipment that creates an electromagnetic field, for example, mo-
tor and generator.
For maintenance and checking, leave enough space at the sides and rear of the unit. Refer to
the outline drawing and provide some additional length in cables.
Follow the recommended compass safe distances shown on page i to prevent the interference
to a magnetic compass.
How to install the CU
Follow the procedure shown below to install the CU on a desktop. See the outline drawing on page
D-3 for details.
1. Place the template (supplied) of the CU on the installation site.
2. Mark the points for four pilot holes and makes the pilot holes for 5x50 self-tapping screws.
3. Put the unit on the installation site and fix it with four 5x50 self-tapping screws (supplied).
Note: It is necessary to install the Communication Unit on a desktop to comply with IPX2 (drip-
ping) standard. Refer to section 2.5 for directions to how to install on a desktop.
350±0.5 mm (13.78")
52.5 mm
(2.07")
160±0.5 mm (6.30")
375 mm (14.76")
SIM CARD INSIDE
POWER OFF BEFORE INSERTING
OR REMOVING SIM
POWER
I
POWER
1
TX
234
STATUS
Inmarsat FleetBroadband
READY
4-
φ
6 mm (0.24")
Fixing holes