Magnum 1000 Workgroup Hubs Installation and User Guide (04/02)
9
www GarrettCom com
..
Figure 2.3b: Model 1024 Internal Connections, Basic AUI port and Bonus Port
2.4 Bonus Port Configuration Options - RPMs and BPMs
Magnum 1000 Workgroup Hubs may be configured with any Repeater Port
Module (RPM) or Bridge Port Module (BPM) in the rear bonus port. (For the 1008, this
is done by exchanging the basic AUI port for a Port Module). An RPM may be used to
provide connectivity, such as to a backbone, via any standard Ethernet media. A BPM
may be used to provide local-bridge isolation for the 1000 Workgroup Hub’s users.
RPMs are available for the following six Ethernet connector types: BNC
(ThinNet or 10BASE2), AUI (10BASE5 or ThickNet, DB-15 female for most
transceiver connections), DTE (DB-15 male-AUI for direct connects), ST (Ethernet
multi-mode Fiber ST), SMF (Ethernet single-mode Fiber), and RJ-45 (10BASE-T UTP
and STP). They are shown in Figure 2.4a.
Figure 2.4a: Magnum RPM Cards: RPM-BNC, RPM-AUI,
RPM-DTE, RPM-FST, RPM-SMF & RPM-TP.
J1
J1-RPM
J4-RPM
J4
Bonus port for optional
PM card (BPM shown)
Basic AUI port
PM Ribbon cable with 16 pin headers.
(Included only when PM is factory installed.
May be ordered separately as part # CBL-PM)
NOTE:
Use J1 and J4 for Basic AUI ports
Use J1-RPM and J4-RPM for PMs
J4-RPM
J4