Magnum 1000 Workgroup Hubs Installation and User Guide (04/02)
1
www GarrettCom com
..
1.0 SPECIFICATIONS
1.1 Technical Specifications
Performance
Data Rate: 10Mbits / sec
Partitioning: Enforced after 32 consecutive collisions.
Reconnect: Occurs after 512 bits of error-free transmission.
Network Standards
Ethernet V1.0/V2.0 IEEE 802.3: 10BASE-T, 10BASE5, 10BASE2,
10BASE-FL & FOIRL.
(Magnum Workgroup Hubs are physical layer standard Ethernet products,
and operate independently of all software.)
Maximum Ethernet Segment Lengths
DTE (AUI Drop Cable) - 50 m (164 ft)
10BASE-T (twisted pair) - 100 m (328 ft)
Shielded twisted pair - 150m (492 ft)
10BASE2 ThinNet (BNC) - 185 m (607 ft)
10BASE5 ThickNet - 500 m (1,640 ft)
FOIRL multi-mode Fiber optic - 1 km (3,281 ft)
10BASE-FL multi-mode Fiber optic - 2 km (6,562 ft)
Single-mode Fiber optic - 10 km (32,810 ft)
Connectors
TP : RJ-45 shielded, female
AUI: D-sub 15-pin female with slide lock
Other Media: via Port Modules
AC Power: IEC recessed male
Switches
Port 1, up-link switch for repeater-to-repeater connections.
LEDs
PWR (AC power on), ACT (common activity indicator), LINK (per port)
Operating Environment
Ambient Temperature: 32° to 120° F (0° to 50°C)
Storage Temperature: -5° to 140°F (-20°to 60°C)
Ambient Relative Humidity: 10% to 95% (non-condensing)
Packaging
Enclosure: High strength metal. Suitable for wiring closet shelf,
desktop, or rack-mounting.
Dimensions: 1008: [8.5 x 7.75 x 1.75] in, [21.6 x 19.7 x 4.5] cm
1016 & 1024:[17.0 x 7.5 x 1.75] in, [43.2 x 19.1 x 4.5] cm
Weight: 1008: 3.4 lbs, 1.6 kg
1016: 3.1 lbs, 1.4 kg
1024: 3.3 lbs, 1.5 kg
Cooling method: Convection