GE GXSL55R Computer Drive User Manual


 
Performance Data Sheet.
SmartWater Filtration System GXSL55R Using Filter FQSLF
This System has been tested according to NSF/ANSI 42 and 53 for the reduction of the substances listed below. The concentration of the indicated
substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system,
as specified in NSF/ANSI 42 and 53.
Actual performance may vary with local water conditions.
WARNING:
Do not use with water that is microbiologically unsafe or with water of unknown quality without adequate disinfection
before or after the system. Systems certified for cyst reduction may be used on disinfected waters that may contain filterable cysts.
5
Standard No. 42: Aesthetic Effects
USEPA Influent Influent
Effluent % Reduction
Min. Required
Parameter MCL Challenge Concentration Average Average Maximum Average Minimum Reduction
Chlorine 2.0 mg/L + 10% 2.00 mg/L 0.050625 mg/L 0.06 mg/L 97.52% 97.00% >50%
T & O
Nominal Particulate**
at least 10,000 particles/mL 14,000,000 #/mL 196,666 #/mL 370,000 #/mL 99.00% 97.40% >85%
Standard No. 53: Health Effects
USEPA Influent Influent
Effluent % Reduction
Min. Required
Parameter MCL Challenge Concentration Average Average Maximum Average Minimum Reduction
Turbidity 0.5 NTU*** 11 + 1 NTU*** 10.5 NTU 0.125 NTU 0.30 NTU 98.80% 97.30% 0.5 NTU
Cysts 99.95% red. Minimum 50,000 L 122,500 #/L <1 #/L <1 #/L >99.99% >99.99% >99.95%
Asbestos 99% red. 10
7
and 10
8
; 126.5 MF/L <.17 MF/L <.17 MF/L >99.99% >99.99% >99%
fibers >10 micrometers long
Lead, pH 6.5 0.010 mg/L 0.015 mg/L + 10% 0.150 mg/L <0.001 mg/L <0.001 mg/L >99.30% >99.30% 0.010 mg/L
Lead, pH 8.5 0.010 mg/L 0.015 mg/L + 10% 0.150 mg/L <0.001 mg/L <0.001 mg/L >99.30% >99.30% 0.010 mg/L
Mercury, pH 6.5 0.002 mg/L 0.006 mg/L ± 10% 0.006 mg/L 0.0003 mg/L 0.0005 mg/L 95.00% 91.70% 0.002 mg/L
Mercury, pH 8.5 0.002 mg/L 0.006 mg/L ± 10% 0.0059 mg/L 0.00073 mg/L 0.0018 mg/L 88.10% 69.20% 0.002 mg/L
Atrazine 0.003 mg/L 0.009 mg/L + 10% 0.0102 mg/L 0.00105 mg/L 0.0027 mg/L 89.40% 76.30% 0.003 mg/L
Lindane 0.0002 mg/L 0.002 mg/L + 10% 0.0019 mg/L 0.000035 mg/L 0.00016 mg/L 97.90% 91.80% 0.0002 mg/L
2,4-D 0.07 mg/L 0.200 mg/L ± 10% 0.2005 mg/L 0.017575 mg/L 0.064 mg/L 84.90% 69.00% 0.07 mg/L
Toxaphene 0.003 mg/L 0.015 ± 10% 0.015 mg/L <0.001 mg/L <0.001 mg/L >93.30% >93.30% 0.003 mg/L
*Tested using a flow rate of 0.78 gpm (2.95 l/min); pressure of 60 psig; pH of 7.5 ± 0.5; temp. of 68° ± 5°F (20° ± 3°C)
**Measurement in particles/mL. Particles used were 0.5–1 microns.
***NTU—Nephelometric Turbidity Units
Operating Specifications
Capacity: certified for up to 1200 gallons (4,542 l); up to six months
Pressure requirement: 35–120 psi (2.8–8.2 bar)
Temperature: 33–100°F (0.6–38°C)
Flow rate: 0.78 gpm (2.95 l/min)
Replacement Filter Canisters/Estimated Replacement Costs
FQSLF—Replacement filter canister $30–35
For replacement parts, call toll-free 800.626.2002 (U.S.),