GE THQL1120AFP2 Network Hardware User Manual


 
Main Lugs Factory Installed (TLM units convertible to main breaker),
Outdoor (NEMA 3R) Enclosure
1
Main 1 Pole, 2 Pole, 1 Pole, 2 Pole, Total Main Wire Size
Ampere 1” 1” 1/2” 1/2” 1-pole Front Feed
1
Box (AWG/kcmil) Equipment Product
Rating Spaces Spaces Spaces Spaces Spaces Type Type Number Cu-Al Ground Kit Number
40 21 41 4 Top R1A 14-4 TGK4 (order separately) TL240RCU
70 21 41 4 Top R1A 6-3 TGK4 (order separately) TL270RCU
100 50 00 5Flush Top R41 6-3 TGL1 installed TL510RT
2,8
125 42 83 8 Top R1A 1-2/0 TGL1 (order separately) TL412R1
2
125 42 83 8 Top R1A 1-2/0 TGL1 installed TL412RT1
2
125 42 83 8 Top R41 1-2/0 TGL1 (order separately) TL412R2
2
125 42 83 8Thermoplastic Top R1 1-2/0 TGL1 (order separately) TPL412R
2,3
Front
125 42 83 8Thermoplastic Top R1 1-2/0 TGL1 installed TPL412RT
2,3
Front
125 4312 4 12 Top R2A 6-1 TGK12 (order separately) TLM612RCU
4
125 8416 8 16 Top R2A 6-1 TGK12 (order separately) TLM812RCU
4
125 8416 8 16 Top R3A 6-1 TGK12 (order separately) TLM812RCU2
5
125 14 6 20 8 24 Top R3A 6-2/0 Included TLM1212RCU
7,9
125 24 12 00 24 Top R4A 6-2/0 TGK24 (order separately) TLM2412RCU
5
Bottom TGK32 (order separately)
150 24 12 12 4 30 Top R6A 1-3/0 (Cu), TGK24 (order separately) TLM2415RCU
6
Bottom 2/0-3/0 (Al) TGK32 (order separately)
200 12 6 24 10 24 Top R5A 6-250 TGK24 (order separately) TLM1220RCU
6
200 16 8 32 14 32 Top R5A 6-250 TGK32 (order separately) TLM1620RCU
6
200 20 10 40 18 40 Top R6A 6-250 TGK24 (order separately) TLM2020RCU
6
TGK42 (order separately)
200 24 12 36 18 42 Top R39 1-250 (Cu), TGK24 (order separately) TLM2420R42
Bottom 2/0-250 (Al)
200 32 16 16 6 40 Top R7A 1-250 (Cu), 2/0-250 (Al) TGK32 (order separately) TLM3220RCU
6
Bottom
200 40 20 00 40 Top R8A 6-250 TGK42 (order separately) TLM4020RCU
6
Bottom
225 42 20 00 42 Top R8A 1-300 (Cu), TGK42 (order separately) TLM4222RCU
6
Bottom 2/0-300 (Al)
1
40-225 amp single-phase devices have removable closing caps. Larger ampere devices require field-cut openings. Order hubs separately. See page 1-27.
2
10 kAIC.
3
125 amp maximum branch capacity.
4
For main breaker, order THQLRK2 retainer kit plus 2-pole circuit breaker. See page 1-28, 100 amp maximum due to wire bending requirements.
5
For main breaker, order TQMH000. See page 1-24. Also order 2-pole THQL or THHQL circuit breaker. See page 1-5.
6
For main breaker, order THQMVXXXD circuit breaker from page 1-6.
7
For main breaker applications, use reverse feed THQL or THHQL circuit breaker (see page 1-5) and THQLRK3 breaker retainer (see page 1-28).
8
Main and branch breakers are limited to 70 amps.
9
Load center includes a factory installed ground bar and add-a-lug. See wiring diagram on page 1-30. A separate TGL2 can be added in the unlikey event
that another ground bar is required.
Note: See page 11-4, AL Series Lighting Panelboards as replacements for 300-600A load centers.
Rev. 11/13
Data subject to change
without notice
1-11
BuyLog
Catalogwww.geindustrial.com
Section 1
Load Center
1PH
Main Lug
Outdoor NEMA 3R
Load Centers and Circuit Breakers
PowerMark Gold and Plus Load Centers
Single-Phase, Three-Wire, 120/240 Vac
Main Lugs Convertible to Main Breaker