Gefen EXT-DPKVM-441 Switch User Manual


 
22
RS-232 COMMANDS
#LOCKPOWER Command
The #LOCKPOWER enables/disables the power lock state. Enabling this
feature will store the 5V status for each input prior to shutting the unit down.
This preserves the 5V state when the unit is restarted.
Syntax:
#lockpower param1
Parameters:
param1 State [0 - 1]
Value Meaning
0 Disable Power Lock
1 Enable Power Lock
#STBYMODE Command
The #STBYMODE command toggles the Standby Mode state. When the
Switcher is powered OFF (not unplugged), then the unit is in Standby Mode.
Executing this command from Standby Mode will power ON the Switcher.
Syntax:
#stbymode param1
Parameters:
param1 Mode [0 - 1]
Value Meaning
0 Normal Mode
1 Standby Mode